LUMINELL RLX DxZ1.21 Скачать руководство пользователя страница 4

 

 

  

 

Luminell Norway AS 

Doc. Nr.: L0482 

 RLX DxZ1.21 User Manual  v.1.7 

Page 4 of 9 

 

8

 

M

ECHANICAL INSTALLATION

 

To attain the long lifetime, please make sure that the heat sink on the back of the chassis has an adequate 
passage to allow air to flow freely 

 this for the highest possible cooling performance.  

For detailed mechanical drawings see appendix. 

The RLX DxZ1.21 may be mounted in any direction, however it is recommended to point the cable glands 
downwards.  

8.1

 

G

ASKET AND 

C

OVER

 

 When removing the back cover on the terminal box note following;  

-

 

There is no fall protection on the bolts apart 
from the hold in the gasket.

 

-

 

Be aware that the bolts may loosen from the 
clamp of the gasket, if they are mechanically 
pushed.  

-

 

Upon mounting, ensure all gasket areas are 
free from any foreign objects. 

-

 

If the silicone grease has been wiped off, then 
add new silicone grease (Loctite OKS1110 or 
similar) 

-

 

Tighten the 5x M6 bolts with 6 Nm. 

 

8.2

 

S

AFETY WIRE

 

The holes for safety wire are tested to withstand a 2m fall. It is recommended always to have wires as short 
as possible. ONLY use dedicated holes for safety wires. See appendix for detailed drawings.  

8.3

 

A

DJUSTING 

L

IGHT 

B

EAM 

D

IRECTION

 

Due to the variations of beam angle alternatives, it is important to notice the difference 
between these and how each beam will illuminate the desired area. It is essential that 
the floodlight is mounted and pointing according to the light simulation or as intended.  

Visit 

www.luminell.com

 or scan the QR code to understand how the different light beam 

angles illuminate.  

Содержание RLX DxZ1.21

Страница 1: ...fshore conditions Remarkable EMC EMI characteristics No maintenance no flame path Prepared for GEL filled connection box CONTENTS 1 GENERAL 2 2 SAFETY 2 3 TYPE OVERVIEW 2 4 MARKING 3 5 CERTIFICATE 3 6...

Страница 2: ...on contained in these operating instructions the data and rated operating conditions disposal of waste parts or floodlight in accordance with national regulations the ATEX or IECEx certificate the equ...

Страница 3: ...Voltage Input AC 100 277 VAC 50 60Hz DC 100 300 VDC Current 240W 1 05 A 230 VAC Power factor cos 0 98 Consumption 80 160 or 240 W Nominal Rating Ambient Temperature 55 C Ta 55 C IP rating IP66 67 Weig...

Страница 4: ...the gasket if they are mechanically pushed Upon mounting ensure all gasket areas are free from any foreign objects If the silicone grease has been wiped off then add new silicone grease Loctite OKS111...

Страница 5: ...ternal electronics only cable and a variable or fixed resistor s Resistant to electromagnetic disturbance 0 10 V External low voltage supply up to 10 VDC Very common method for DIM control The RLX DxZ...

Страница 6: ...made to be maintenance free and only occasional cleaning without solvent is recommend to ensure light output and cooling Do not paint Material combination and surface treatment has been carefully sel...

Страница 7: ...Luminell Norway AS Doc Nr L0482 RLX DxZ1 21 User Manual v 1 7 Page 7 of 9 13 APPENDIX 13 1 DIMENSIONS...

Страница 8: ...4 5 13 2 MOUNTING 13 3 ACCESSORIES See Luminell com for all available accessories 1 1002600 Connection box gel kit 2 1002322 Pole Mount bracket 30 100 3 252 Protection Guard Set 4 1002629 Retrofit br...

Страница 9: ...nell Norway AS Doc Nr L0482 RLX DxZ1 21 User Manual v 1 7 Page 9 of 9 13 4 LIGHT BEAM ILLUSTRATIONS Structured glass Clear glass Types Oval 45x15 Medium 60x40 Wide 80x60 Types Spot 15 Medium 40 Medium...

Отзывы: