background image

 

 

  

 

Luminell Norway AS 

Doc. Nr.: L0482 

 RLX DxZ1.21 User Manual  v.1.7 

Page 2 of 9 

 

1

 

G

ENERAL

 

The RLX DxZ1.21 is a compact and solid LED floodlight created to last in very harsh and corrosive 
environments. It is designed to be used both in gas and dust environments, zones 1, 2, 21 and 22. 

Read this user guide to get the most out of your RLX DxZ1.21 LED floodlight and help it to maximize its 
potential for your application.  

 

2

 

S

AFETY

 

Inappropriate or unauthorized use or failure to comply with the information contained in these 
instructions, voids any warranty and may invalidate the certificate.  Modifications or changes to the 
equipment are not allowed.  
 
The following must be observed by the installer and end user:  

 

national safety regulations  

 

national workplace health and safety regulations  

 

national installation and set-up regulations  

 

generally accepted engineering standards  

 

the safety information contained in these operating instructions  

 

the data and rated operating conditions 

 

disposal of waste, parts or floodlight in accordance with national regulations 

 

the ATEX or IECEx certificate 

 

the equipment is suitable for harmful or corrosive chemicals that may be 
present. 

 
For the installation and operation of explosion-protected equipment, the 
recognized rules of technology in accordance with EN60079-

14 “Configuring and 

selection”, and EN60079

-

17 “Test and maintenance”, and the accompanying 

installation and operating instructions must be observed. Luminell reserves the 
right to make technical changes to the product without notice.  

 

 

3

 

T

YPE 

O

VERVIEW

 

 

 

 

 

 

 

RLX DxZ1.21 Type and 
Power consumption 

 Temperature Class 
and rating 

Input Voltage 

Light Beam Alternatives 

240 W 

 

T4       -

55°C ≤ Ta ≤ 55°C

 

VAC: 
100 - 277 VAC   50-60 Hz 
 
VDC: 
100-300 VDC 

-

 

Spot 15 

-

 

Oval 45 x 15 

-

 

Medium 40 

-

 

Medium 60 

-

 

Medium 60 x 40 

-

 

Wide 80x60 

160 W 

 

T5       -

55°C ≤ Ta ≤ 55°C

 

80 W 

T6       -

55°C ≤ Ta ≤ 55°C

 

 

 

Do not open when 
energized.  

Crush hazard!

  

Be aware of moving parts 
when lifting and mounting 
the floodlight. Shall only 
be installed by a qualified 
electrician. 

Содержание RLX DxZ1.21

Страница 1: ...fshore conditions Remarkable EMC EMI characteristics No maintenance no flame path Prepared for GEL filled connection box CONTENTS 1 GENERAL 2 2 SAFETY 2 3 TYPE OVERVIEW 2 4 MARKING 3 5 CERTIFICATE 3 6...

Страница 2: ...on contained in these operating instructions the data and rated operating conditions disposal of waste parts or floodlight in accordance with national regulations the ATEX or IECEx certificate the equ...

Страница 3: ...Voltage Input AC 100 277 VAC 50 60Hz DC 100 300 VDC Current 240W 1 05 A 230 VAC Power factor cos 0 98 Consumption 80 160 or 240 W Nominal Rating Ambient Temperature 55 C Ta 55 C IP rating IP66 67 Weig...

Страница 4: ...the gasket if they are mechanically pushed Upon mounting ensure all gasket areas are free from any foreign objects If the silicone grease has been wiped off then add new silicone grease Loctite OKS111...

Страница 5: ...ternal electronics only cable and a variable or fixed resistor s Resistant to electromagnetic disturbance 0 10 V External low voltage supply up to 10 VDC Very common method for DIM control The RLX DxZ...

Страница 6: ...made to be maintenance free and only occasional cleaning without solvent is recommend to ensure light output and cooling Do not paint Material combination and surface treatment has been carefully sel...

Страница 7: ...Luminell Norway AS Doc Nr L0482 RLX DxZ1 21 User Manual v 1 7 Page 7 of 9 13 APPENDIX 13 1 DIMENSIONS...

Страница 8: ...4 5 13 2 MOUNTING 13 3 ACCESSORIES See Luminell com for all available accessories 1 1002600 Connection box gel kit 2 1002322 Pole Mount bracket 30 100 3 252 Protection Guard Set 4 1002629 Retrofit br...

Страница 9: ...nell Norway AS Doc Nr L0482 RLX DxZ1 21 User Manual v 1 7 Page 9 of 9 13 4 LIGHT BEAM ILLUSTRATIONS Structured glass Clear glass Types Oval 45x15 Medium 60x40 Wide 80x60 Types Spot 15 Medium 40 Medium...

Отзывы: