LUMINELL RLX D Скачать руководство пользователя страница 5

 

 

  

 

Luminell Norway AS 

Doc. Nr.: L0588 

 RLX D User Manual  v1.2 

Page 5 of 7 

 

5

 

  

E

LECTRICAL 

I

NSTALLATION

 

Risk of electric shock. Ensure that power is disconnected before carrying out any connections. 

Both the power and dimming connection can be parallel (or in-line) connected. If so, ensure 
to use suitable cables due to the increased current running through the junction box and 
spring terminals.  

5.1

 

     

C

ABLE CONNECTIONS

 

 

 

5.1.1

 

Dimming Connection (slot 7-10)  

On the positive and negative DIM wire connection, it is possible to control the floodlight in three different 
ways. The dimming range is approx. from 0% up 100% light output. 

Interface 
All on the same 
connection: DIM +/- 

Signal specifications 

Comment 

Resistance 

One floodlight:  0-

100 kΩ

 corresponds to 0-100% 

light output 
Several floodlights(n) p

arallel connected:  100 kΩ/n. 

Eg. 4x floodlight controlled together would require a 

25 kΩ variable resistor or potentiometer.

 

It is recommended to use logarithmic resistors, since 
the sensitivity is greatest when resistance is small. If 
nothing is connected the output is 100% 

Very simple to set up. Requires 
no external electronics, only 
cable and a variable or fixed 
resistor(s). Resistant to 
electromagnetic disturbance. 

0-10 V  

External low voltage supply up to 10 VDC.  

Very common method for DIM 
control. The RLX D has a built-in 
delay for stable and reliable 
control and resistance to 
electromagnetic interference. 

4-20 mA 

External constant current source.  Adjusting the 
current from 4-20mA at a nominal voltage of 24 
VDC. Only one floodlight per 4-20mA controller.  

Not affected by 
electromagnetic disturbances. 

5.1.2

 

Startup current 

A startup current is needed to energize the electronics inside the RLX D LED floodlight. When using a 
MCB16 Type C fuse, approx. 11 RLX D floodlights can be started at once. The inrush current is the equal for 
all power alternatives.  

Function 

AC/DC (position) 

Description 

Wire cross section 

Power Grid 
Connection 

L / 

+

 

(1,2) 

Phase / +  

0,2 <6mm

2

 

N / 

-

 

(3,4) 

Neutral / -
conductor   

0,2 <6mm

2

 

PE

 (5,6) 

Earth 
connection  

0,2 <16mm

2

 

DIM connection 
See 9.1.1 

DIM

 +

  (7,9) 

Positive DIM  

0,1 <2,5mm

2

 

DIM 

-

  (8,10) 

Negative DIM 

0,1 <2,5mm

2

 

ONLY

 Luminell 

battery backup 
Acc. Connection  
(Separate 
product) 

 (11) 

LED/PSU 
positive  

0,1 <2,5mm

2

 

-   (12) 

LED/PSU 
negative 

0,1 <2,5mm

2

 

 (13) 

Control signal 

0,1 <2,5mm

2

 

N

  (14) 

Temperature 
sensor 

0,1 <2,5mm

2

 

More illustrations in appendix 