IMPORTANT, PLEASE READ.
This is an electrical appliance, use appropriate precautions
to reduce risk of fire, electrical shock or injury.
• Read all instructions before installing / using the unit.
• Do not use outdoors unless in protected area. (inquire)
• To disconnect unit, turn control OFF and disconnect
power at the service panel.
• Always use a licensed electrician should new circuits or
outlets be needed.
• Disconnect power supply before performing any cleaning,
maintenance or relocation of unit.
INSTALLATION / ELECTRICAL
The AQ1000 and AQ500 come ready for hard wire installation
& manually filled water containers. (can be direct plumbed)
!
NOTE
:: A 15 Amp, 120 Volt circuit is required. A dedicated
circuit is preferred but not required.
• Keep unit in OFF position before connecting electrical power.
!
NOTE
:: When preparing the opening for the unit provide
at least 1⁄4 inch of clearance from each side to make
installation easier.
Caution
:: Use two conductor, non-metallic sheath
cable with ground wire (3 wires total) for incoming power
supply on cassette. Use appropriate wire to meet local and
national electrical codes for rated power.
!
NOTE
::
When installing multiple units in same
vicinity they will need to be wired in parallel.
• The AQUAFIRE cassette allows for installation of a wall
switch to control incoming power to unit.
• Connect black wire (live) from unit to live wire from power
supply. Connect white wire (neutral) from unit to neutral
wire from power supply. Connect green wire (ground) from
unit to ground wire from power supply.
• Place all connectors inside unit and secure cable clamp
to unit, making sure that cable clamp grips only jacket of
service cable.
!
Warning
:: Ensure wiring is not pinched or against a sharp
edge, ensure power wiring is stored to avoid tripping or
snagging to reduce fire risk, electric shock or injury.
Optional Direct Plumbing
(see Figure 2)
Units are designed to be manually filled or direct plumbed.
One 1/4“ waterline can supply water for up to four units in
series. More than four units will require additional water lines.
• Use self-tapping saddle valve for 1/4“ copper
water water lines (recommended).
• All plumbing connections should comply with
local building codes.
• Locate plumbing connection for easy access allowing
shut off during maintenance.
• Connect to cold water line.
• Use normal tap water. If water is ‘hard’, soften or filter it.
• Be sure tubing is cut square to prevent leaking.
• Verify all connections are fully inserted and begin opening
each of the valves, checking for leaks.
!
NOTE
:: Unit has three levels of water control management.
Lumina Products Inc
™
www.luminaproducts.com
p: +1
877.395.0888
AQ1000 40“ AQUAFIRE MODULE
AQ500 20“ AQUAFIRE MODULE
AQUA
FIRE
SETUP GUIDE
IMPORTANT :: For your safety, read this manual first before
attempting to install or use this AQUAFIRE unit. Failure to
comply with all warnings and safety instructions contained
in this manual could result in personal injury or property
damage. If you have questions, please call 877.395.0888.
Figure 1