0158
• Description:
The VISULEX K55P-Ex/K55N-Ex is a fixed-lens camera.
During the installation process, the lens of this standard
camera is focused on the outdoor area or facility to be kept
under surveillance (e. g. yard, plant or technical process
elements such as vessels or agitators).
The temperatures specified in the data sheet for the built-in
camera type should be observed so as to ensure trouble-free
operations. A terminal box is provided for connecting the
camera. Important, please note: Under no circumstances
should a camera be used to replace the cover flange or the
complete sight glass fitting, nor should it be used on its own
as a closure for a vessel port.
• Design and field of application:
- Pressure-resistant stainless steel housing with built-in
colour CCD camera, 1/3” CCD sensor, 1 lux photosensitivity,
electronics, and stainless steel mounting
- Approved for Ex zones 1 and 2 as well as zones 21 and 22
• General electrical data:
- Feed voltage to the camera: 12 V/DC ± 10%
- Maximum power consumption: 7.5 W including power
supply unit
- Protection class of camera: IP65 acc. to EN 60529/
DIN VDE 0470, Part 1
- Application temperature range: -10°C to +45°C
(depending on camera module used)
- Protection class of terminal box: IP40
- Ex approval acc. to EC type examination certificate:
BVS 15 ATEX E 056 X
II 2G Ex d IIC T6 Gb
II 2D Ex tb IIIC T80°C Db
• Markings:
The camera has a permanent type plate which is clearly
visible and easy to read. It bears the following data:
- Name and address of manufacturer
- Camera type: K55P-Ex
- Ambient temperature range: -20°C
≤
Ta
≥
+50°C,
depending on the camera module used
- Certificate number
- Warning – must be observed:
- Do not open when live!
- After deactivating the voltage, wait four minutes before
opening
- Serial number/year of manufacture
- Supply voltage
- Protection class: IP65
- CE symbol/No. of certification body
• Connecting cable:
The connecting cable is to be installed so as to avoid the
occurrence of static charges. The length of the supply cable
has to be max. 1 m.
• Connection:
- The camera is supplied as a unit comprising the camera
and the terminal box.
- Should it be necessary to detach the connecting cable to
improve the cable routing, this can be carried out in the
terminal box.
- The camera should never be operated without the terminal
box because the safety device (fuse) is located in the
terminal box.
F.H.Papenmeier GmbH & Co. KG · division Lumiglas
Talweg 2 · 58239 Schwerte · Germany
phone: +49-2304 205-0 · fax: +49-2304 205-206
[email protected] · www.lumiglas.de
Installation and Operating Instructions
0093.117.00 b
Attaching the cable in the terminal box
VISULEX Ex Camera K55P-Ex/K55N-Ex
II 2G Ex d IIC T6 Gb
II 2D Ex tb IIIC T80°C Db
VISULEX Camera K55P-Ex
with fixed lens