background image

User Manual

User Manual_Magicube series_KE

CE, Rohs, ISO9001:2015

Subject to change without notice!

MPPT

 

Solar Controller

12/24V

20/40A,

260/520/1KW

Magicube

 

series

Magic your solar life

Lumiax

www.lumiax.com

1.03.02.10043-1

Содержание Magicube Series

Страница 1: ...l User Manual_Magicube series_KE CE Rohs ISO9001 2015 Subject to change without notice MPPT Solar Controller 12 24V 20 40A 260 520 1KW Magicube series Magic your solar life Lumiax www lumiax com 1 03...

Страница 2: ...Mounting Location Requirements 7 5 3 Wiring Specifications 8 5 4 Connection 9 5 5 Grounding 9 6 Operation 9 6 1 LED Indicator 9 6 2 Key Function 10 6 3 LCD Display 10 6 4 Parameters setting 12 7 Prote...

Страница 3: ...installing operating and monitoring Read it with special care in your own interest and please pay attention to the safety recommendations herein indicated 1 2 The manufacturer shall not be liable for...

Страница 4: ...esign Extends battery life through accurate remote temperature sensor Controller is protected against over temperature due to built in power reduction function Magicube series solar controller is base...

Страница 5: ...n should provide Voc vs temperature data Higher solar input voltage results in lower solar input current for a given input power High voltage solar input strings allow for smaller gauge solar wiring T...

Страница 6: ...e is to offset the power consumption caused by self consumption and small loads in the whole system while maintaining full battery storage capacity In Float stage loads can continue to draw power from...

Страница 7: ...3 Dimensions 3 1 The dimensions of MC2010 Unit mm 3 67 10 136 60 136 60 120 00 71 00...

Страница 8: ...117 00 120 00 3 2 The dimensions of MC4010 196 50 136 60 67 10 4 Unit mm...

Страница 9: ...ad Battery Terminals Connect the battery Solar module terminals Connected solar modules Heat Sink dissipate controller heat Plastic Case Internal protection LED LCD Display settings and operating stat...

Страница 10: ...ontroller Modbus Communication Protocol V3 9 1 This icon in this specification indicates that this solar controller has Bluetooth communication function 2 Refer to Bluetooth APP instructions for detai...

Страница 11: ...hazard that may occur Never install handle with batteries alone Avoid touching or short circuiting wires or terminals Be aware that voltages on given system components terminals or wires can be a mult...

Страница 12: ...the battery voltage is between the 5 0 and 15 5 Vdc voltage range for 24 Vdc nominal voltage the battery voltage should be within the 20 0 to 31 0 Vdc range Voltages are identifiable when the controll...

Страница 13: ...V system battery must be selected according to rated currents Please check following table for wiring specifications controller or between the controller and the battery are required than larger capac...

Страница 14: ...current The total discharge ampere hours of the load Load mode Programmable Mode 6 2 Key function Browse interface Static display Short press OK Press the MENU and OK key at the same time for 1s the L...

Страница 15: ...6 3 3 Press OK to browse the interface 6 3 2 The interface automatically cycles in the displayed sequence 11...

Страница 16: ...e is 9 6 31 0V default 12 0V The low voltage recovery voltage LVR should be higher than the low voltage protection voltage LVD at least 0 6 1 2V If it is desired to improve LVD than LVR must improved...

Страница 17: ...et voltage range 10 0 32 0V default 14 4V Charge recovery voltage setting range 9 2 31 8V default 14 0V Charging Voltage Parameters Li Note Overcharge Recovery Voltage 1 5V Lithium Overcharge Protecti...

Страница 18: ...the controller turns off the load due to low voltage protection overcurrent protection short circuit protection or over temperature protection the load will turn on automatically when the controller...

Страница 19: ...n voltage of lithium battery equals target voltage plus 0 2V the controller will stop charging to protect the battery from overcharging damage When battery voltage drops to the low voltage disconnect...

Страница 20: ...ge 1 0V Voc 0 9 20A 30A Always on Street lamp User defind Mode 99 9 98 0 136 6 136 6 67 1mm 196 5 136 6 97 1mm 830g 1 3Kg 12mA RS485 RJ11 interface IoT Cyber BT Common Negative 6AWG 16mm 20 55 25 80 0...

Страница 21: ...136 6 97 1mm 830g 1 3Kg 12mA Bluetooth or RS485 RJ11 interface IoT Common Negative 6AWG 16mm 20 55 25 80 0 100 RH IP32 4000m Item Max Charging Current System Voltage MPPT Charging Voltage Boost Volta...

Страница 22: ...nversion Efficiency Charging Power W Charging Power W 0 0 30 60 60 120 90 180 120 240 150 300 180 360 210 420 240 480 260 520 92 92 93 93 94 94 95 95 96 96 97 97 98 98 18V 36V 36V 54V 72V 99 99 12V So...

Страница 23: ...0 40 80 80 160 120 240 160 320 200 400 240 480 280 560 320 640 360 720 400 800 440 880 480 960 520 1040 92 92 93 93 94 94 95 95 96 96 97 97 98 98 18V 36V 36V 99 99 12V 18V 36V Solar Module MPP Voltag...