GF8905-1A-INS-LAB-RevC14
1
GF8905-1A: DELUXE TILT OVERBED TABLE
ASSEMBLY & OPERATION INSTRUCTIONS
PLEASE SAVE THESE INSTRUCTIONS FOR FUTURE USE
Info: The most current version of these instructions can be found online at
www.grahamfield.com
.
Tools needed: Phillips screwdriver,
9
/
16
hex wrench,
5
/
16
hex wrench
WARNING: Important! Read and understand these instructions before assembling or using the
GF8905-1A Overbed Table. If you do not understand any part of these instructions, contact a
healthcare professional for direction in the use of this product. If the Overbed Table is not properly
assembled and adjusted, personal injury and/or damage to the Overbed Table could result.
WARNING: If components are damaged or missing, contact your dealer immediately. DO NOT
use substitute parts. Use only Lumex replacement parts. Non-Lumex replacement parts could
cause personal injury and/or damage to Overbed Table.
WARNING: Notice for California Customers- California Proposition 65 WARNING: This product
contains a chemical known to the State of California to cause cancer and reproductive or
developmental harm.
WARNING: GF Health Products, Inc. assumes no responsibility for any damage or injury caused
by improper assembly or use of this product.
UNPACKING
1. Check for obvious damage to the carton or its contents. If damage is evident, notify the carrier and your
Graham-Field authorized distributor.
2. Remove all loose packing from the box. Carefully remove all the components from the carton. Components:
Table top, mast, 6 machine screws, base with 4 casters, 2 hex head bolts, 2 flat washers, and 2 metal spacers.
mast mounting plate
mast
machine screw
(6 each)
table top
table top bracket
release
paddle
tilt knob
install mast
lock nut
(6 each)
hex head bolt
(2 each)
spacer (2 each)
mast column
washer (2 each)
base
table
transit lock screw
install base
transit lock screw
release
paddle
locking
casters
tilt knob
remove transit
lock screw
ASSEMBLY (SEE PICTURES ABOVE)
WARNING: Do not remove the transit lock screw from the mast before the table is completely
assembled; the table top could rise suddenly and cause serious personal injury.
WARNING: Do not disassemble the mast; this could cause serious personal injury.
1. Place the table top upside down on work surface.
2. Position the mast above the table top, oriented as shown at left above. Place mast mounting plate on table
top, matching mast mounting plate holes with table top bracket holes.
3. Mount mast to table top: Install machine screws through mast mounting plate holes and table top bracket
holes. Install nuts on screws. Tighten.
4. Place the base upside down above the mast, oriented as shown at center above.
5. Install the two hex head bolts through the washers, spacers, and base, and into the end of the mast column
as shown. Tighten the bolts.