background image

Alternating Pressure Overlay

Model # 14025

O

Op

peerraatto

orrss M

Maan

nu

uaall

14025-INS-LABRevA05

 

    

 

 

 

 

 

 

 

Содержание AltaDyne 14025

Страница 1: ...AlternatingPressureOverlay Model 14025 O Op pe er ra at to or rs s M Ma an nu ua al l 14025 INS LABRevA05...

Страница 2: ...Contents Important Safeguards 2 Introduction 3 Product Description 4 Installation 6 Operation 8 Cleaning 10 Storage 11 Maintenance 11 Troubleshooting 12 Technical Description 13...

Страница 3: ...ng properly if it has been dropped or damaged or dropped into water Return the product to a service center for examination and repair 5 Keep the cord away from heated surfaces 6 Never block the air op...

Страница 4: ...2 For Europe EN 60601 1 EN 60601 1 2 EN 55011 Class B EN 61000 3 2 EN 61000 3 3 IEC 801 2 IEC 801 3 IEC 801 4 IEC 801 5 1 2 Intended Use This product is intended to help and reduce the incidence of p...

Страница 5: ...4 2 Product Description 2 1 Pump and Mattress System 1 CPR 2 Pump unit 3 Mattress System or Bubble Pad System 4 Quick Connectors...

Страница 6: ...Hose Port Rear 5 Power Cord 2 3 Front Panel 1 Pressure Adjust Knob Pressure adjust knob controls the air pressure output When turning clockwise the output pressure will increase Vice versa for decreas...

Страница 7: ...eshooting 4 Main Power Switch To turn on off the pump unit 3 Installation Unpacking the box to inspect for any damage which may have occurred during shipment If there are any damages please contact yo...

Страница 8: ...switch to ON position Grounding Before any connection to the output connectors is made the unit shall be connected to a protective earth conductor via the three core main cable the mains plug shall b...

Страница 9: ...r yellow LED will light up until the mattress is fully inflated 4 When the appropriate pressure is reached the low pressure indicator yellow LED will go off and normal pressure indicator green LED wil...

Страница 10: ...re is reached to the desired pressure NOTE Check to see if pressure is suitable by sliding one hand between the deflated air cells and the patient to feel s patient s buttock Users should be able to f...

Страница 11: ...e that will have no chemical effects on the surface of the plastic case of the pump unit CAUTION Do not immerse or soak pump unit The cover may also be cleaned using a 10 solution of sodium hypochlori...

Страница 12: ...damage Ensure mattress cover and tubes are attached 3 Check airflow from the air hose The airflow should alternate between each connector every half cycle time 4 Check the air hoses for kinks or break...

Страница 13: ...t be inadequate for the patient adjust pressure to higher level and wait for a few minutes Air Mattress is not secured Check if all the snap buttons or straps of mattress are all securely fastened Che...

Страница 14: ...densing Classification Class I Type BF IPX0 Applied part Air Mattress Not suitable for use in the presence of a flammable anesthetic mixture No AP or APG protection Mattress Specification Model Dimens...

Страница 15: ...if in doubt as to whether the product is properly grounded Note The following instruction applies for 120V system only This product is for use on a nominal 120 V circuit and has a grounding plug that...

Страница 16: ...U S A Corporate Headquarters Graham Field Health Products 2935 Northeast Parkway Atlanta Georgia 30360 telephone 800 347 5678 770 447 1609 fax 800 726 0601 678 291 3232 http www grahamfield com...

Отзывы: