User Manual

 

Version 1.2

 

Содержание OQ LabScope

Страница 1: ...User Manual Version 1 2...

Страница 2: ...nance 3 Residual Risk 4 Service 4 Components 5 Quick Start Basic System Only 6 Quick Start with Workstation Package 8 Software 10 Main Tab 11 Advanced Tab 15 Configuration Tab 17 Hardware 18 System Sp...

Страница 3: ...erates optical depth images of samples System is configured with a scanner that may be used in either a handheld configuration or mounted into a scanner stand An embedded Windows PC provides the user...

Страница 4: ...f the system is used in a manner not specified by the manufacturer then protection provided by the system may be impaired Noise Levels for this equipment were recorded at less than 70 db A Foreseeable...

Страница 5: ...oth Canned air duster may be used to blow dust off of main unit Cleaning scanner scanner may be wiped down with oil free lint free cloth Canned air duster may be used to blow dust off of scanner inclu...

Страница 6: ...Original Instructions Lumedica OQ LabScope 1 2 Page 5 of 26 Components These are your OQ LabScope system hardware components Power Cable Embedded Computer System Chassis Scanner...

Страница 7: ...wer cord into back of OQ LabScope box 5 You will need to supply a monitor with a resolution of 1920 x 1080 and an HDMI interface with cord The software interface is designed for this resolution and ma...

Страница 8: ...button on Main tab 16 OCT image will begin updating 17 Push Update Background to minimize horizontal noise in image 18 Place Scotch tape under handheld scanner and position scanner and tape so that t...

Страница 9: ...andheld scanner into scanner stand If any items are missing please contact us directly at support lumedicasystems com 1 Set up OQ LabScope box within a meter of an electrical outlet 2 Select country c...

Страница 10: ...up OQ LabScope by pushing the button on top of the box 18 Windows 10 OS will boot up and take you to the login screen 19 Login username is oqlabscope 20 Login password is oqlabscope 21 Start OQ LabSco...

Страница 11: ...Original Instructions Lumedica OQ LabScope 1 2 Page 10 of 26 Software The software is started by clicking on the L icon on the taskbar...

Страница 12: ...ing the background so that the OCT image does not become part of the background Save B Scan Image Available when the system is not acquiring OCT images i e the Start Stop button says Start Scan When t...

Страница 13: ...image this slider controls the liquid lens in the scanner Moving the slider up and down sets the focus position of the OCT scanning beam When the slider is at the top of the screen the focus is closes...

Страница 14: ...l to disk This image is saved in both tif and jpg formats The directory where the files are saved is C Users Public Documents Lumedica OctEngine Data The files are named BSCAN SGL date time where date...

Страница 15: ...er and less noisy but will start to suppress the image signal As the slider approaches the top of the range only the most intense areas of the image will still be visible Average B Scan Dynamic Range...

Страница 16: ...ome part of the background Save B Scan Image Available when the system is not acquiring OCT images i e the Start Stop button says Start Scan When this button is pressed the system will save the displa...

Страница 17: ...uffer zero padded to three digits e g 001 The current background subtraction data is also saved in this folder with the name BSCAN BKGD Sliders Focal Value Located to the left of the OCT image this sl...

Страница 18: ...scanning Sliders Scan Width Sets the relative length of the B Scan The longest scan is 1 and it may be shortened down to 0 at which point the scanner is not moving This will give a time series at one...

Страница 19: ...tion 7 m in air 5 m in tissue B Scan Image Rate 12 second System Size 33w x 19d x 15h cm 13w x 7 5d x 6h in Transverse Resolution 15 um C Scan Image Rate Set by number of B scans in C scan Scanner Siz...

Страница 20: ...Original Instructions Lumedica OQ LabScope 1 2 Page 19 of 26 Mechanical Drawings System Chassis Scanner...

Страница 21: ...USB cables running from the computer to other parts of the system You may need assistance holding the top open while making adjustments inside the box Polarization control Inside the OQ LabScope are...

Страница 22: ...e arm tube If the distance from the lens to the mirror is very close to the focal length of the lens then a large amount of power will be reflected back to the interferometer If the mirror is closer t...

Страница 23: ...institute within the EC Currently owned by a company or institute within the EC A complete system not disassembled and not contaminated This service does not cover OEM products that are integrated int...

Страница 24: ...o all shipping expenses Any repair charges will be quoted to the customer and accepted by the customer before any work is performed Warranty Exclusions Warranty does not apply to systems which are 1 c...

Страница 25: ...equires the following steps 1 Contact us by phone or email to discuss any issues and to set up a meeting time and contact phone number 2 At the meeting time start TeamViewer from the icon on the deskt...

Страница 26: ...Original Instructions Lumedica OQ LabScope 1 2 Page 25 of 26 Certifications and Compliance...

Страница 27: ...Original Instructions Lumedica OQ LabScope 1 2 Page 26 of 26 Copyright 2017 by Lumedica Inc 701 W Main St Suite 200 Durham NC 27701 U S A...