background image

M

A

N

U

A

L

O

PE

RA

TI

O

N

M

A

N

U

A

L

IMPAC Pyrometer

IS 140

 IGA 140

All manuals and user guides at all-guides.com

all-guides.com

Содержание IMPAC IGA 140

Страница 1: ...OPERATION MANUAL IMPAC Pyrometer IS 140 IGA 140 All manuals and user guides at all guides com a l l g u i d e s c o m...

Страница 2: ...727 1677 LumaSense Technologies GmbH Other Than North America Sales Support Kleyerstra e 90 60326 Frankfurt Germany Ph 49 0 69 97373 0 Fax 49 0 69 97373 167 Global and Regional Centers Our Headquarte...

Страница 3: ...4 Dimensions 11 2 5 Physical User Interface 12 2 6 Accessories option 12 3 Controls and Installation 15 3 1 Electrical Installation 15 3 1 1 Pin Assignment of the Male Socket on the Back of the Pyrome...

Страница 4: ...Rate Baud 25 5 9 Temperature Display C or F 25 5 10 Wait Time tw 26 5 11 Maximum internal temperature MaxIntTemp 26 5 12 Error Status Status 26 6 Software InfraWin 27 6 1 Connecting the pyrometer to a...

Страница 5: ...harm or damage to equipment MB Shortcut for Temperature range in German Messbereich 1 1 2 Terminology The used terminology corresponds to the VDI VDE directives 3511 part 4 1 2 Safety This manual prov...

Страница 6: ...ion This warranty covers manufacturing defects and faults which arise during operation only if they are the result of defects caused by LumaSense Technologies The Windows compatible software Infrawin...

Страница 7: ...d by telephone or email Santa Clara California Telephone 1 408 727 1600 or 1 800 631 0176 Email support lumasenseinc com Frankfurt Germany Telephone 49 0 69 97373 0 Email eusupport lumasenseinc com 1...

Страница 8: ...the device should be placed in welded foil ideally along with silica gel to protect it from humidity The pyrometer is designed for a storage temperature of 20 to 80 C with non condensing conditions S...

Страница 9: ...rks certificate InfraWin operating and analyzing software Allen key 3 mm user manual Note A connection cable is not included with the instrument and has to be ordered separately See Chapter 10 Referen...

Страница 10: ...s Maximum Minimum Value Storage Built in single or double storage Clearing with adjusted time tclear off 0 01 s 0 05 s 0 25 s 1 s 5 s 25 s extern via interface or automatically with the next measurin...

Страница 11: ...MB 18 350 1800 400 IGA 140 MB 25 450 2500 462 IGA 140 MB 20 300 2000 420 IGA 140 MB 25 350 2500 462 IGA 140 MB 30 300 3000 496 Note The determination of the technical data of this pyrometer is carrie...

Страница 12: ...lectrical connections 11 LC display extended 12 Setting keys 2 6 Accessories option Numerous accessories provide for easy installation of the pyrometer The following overview shows a selection of suit...

Страница 13: ...so be used for remote parametrizing of the pyrometer Digital display DA 6000 Miscellaneous The air purge protects the lens from contamination from dust and moisture It has to be supplied with dry and...

Страница 14: ...IS 140 IGA 140 Manual Introduction 14 To ensure consistent document formatting this page was intentionally left blank All manuals and user guides at all guides com...

Страница 15: ...fers connecting cables but they are not part of standard scope of delivery The connecting cable has wires for power supply interface analog output external laser switch and external clear of maximum v...

Страница 16: ...cted to the housing of the plug on pyrometer side only Video ground and pyrometer housing are galvanically separated The maximum cable length should not exceed 40 m Video output fixed socket model ERA...

Страница 17: ...d rate is reduced by 50 when the transmission distance is doubled see 5 9 Baud rate Typical cable length for 19200 Bd is 2 km 3 1 4 Connection of Additional Analyzing Devices Additional analyzing inst...

Страница 18: ...s blinking and the display shows PILT The laser targeting light can be switched on and off either by pressing the button at the housing or by using an external contact connecting pins H and K or conne...

Страница 19: ...o 16 mm temperature range above 1500 C 8 to 9 mm The aperture is the effective lens diameter It is depending on the objective length The biggest aperture value belongs to the fully extended objective...

Страница 20: ...the laser has its smallest spot size and is illustrated exactly Adjusting the measuring distance with help of the video module The focusable optics is correctly adjusted to the required distance if t...

Страница 21: ...the next parameter and on the display a corresponding short form is displayed see Chapter 5 in brackets behind the parameter names 2 With the arrow keys and all parameter settings can be displayed Pu...

Страница 22: ...elected the temperature shown in the display is 800 C This temperature must be reflected exactly by the indicator which is supplied by the respective current If this is not the case the selected analo...

Страница 23: ...bsorbs all incoming rays and has an emissivity of 100 at the same temperature Different materials have different emissivities ranging from 0 to 100 The emissivity of an object is dependent on the surf...

Страница 24: ...ata format UPP or via an external contact see section 3 1 1 In this case the storage operates only in single storage because only a single deletion mechanism is used auto The auto mode is used for dis...

Страница 25: ...temperature range increases the accuracy of the analog output Additionally setting the subrange makes it possible to fulfill the requirements of the auto clear mode of the maximum value storage 5 7 Ad...

Страница 26: ...e of 2 9600 sec Note The setting of a delay time tw does not guarantee an answer to some commands directly after this time Certain commands require an internal operation time of max 3 ms 5 11 Maximum...

Страница 27: ...the pyrometer to a PC The program InfraWin can operate up to two devices Two devices using RS485 may be operated simultaneously by the same interface if two different addresses have been properly ente...

Страница 28: ...IS 140 IGA 140 Manual Software InfraWin 28 To ensure consistent document formatting this page was intentionally left blank All manuals and user guides at all guides com...

Страница 29: ...ptics for different measuring distances can be used without recalibration of the instrument Replacement can be necessary if the lens is scratched or the pyrometer will be used for other measuring dist...

Страница 30: ...IS 140 IGA 140 Manual Maintenance 30 To ensure consistent document formatting this page was intentionally left blank All manuals and user guides at all guides com...

Страница 31: ...Use mechanical construction to avoid the influence of the interfering radiation Measuring errors Indicated temperature is decreasing during the use of the pyrometer due to contamination of the lens Cl...

Страница 32: ...IS 140 IGA 140 Manual Troubleshooting 32 To ensure consistent document formatting this page was intentionally left blank All manuals and user guides at all guides com...

Страница 33: ...commands not at enquiry commands Example Entry 00em CR The emissivity setting of the device with the address 00 is returned Answer 0970 CR means Emissivity 0 97 or 97 Description Command Parameters Re...

Страница 34: ...Laser targeting light AAlaX X 0 switch off laser X 1 switch on laser Reading interface AAin Output 1 or 2 1 RS232 2 RS485 Lock keyboard AAlkX X 0 3 1 lock lk1 removal with command lk0 or power off on...

Страница 35: ...with limited AAox_ _ space character deletes bit 0 in video status auto reset AAoxTT TT TT TT text with max 12 ASCII sets bit 0 in video status auto reset Time AAot Output time in format HHMMSS 6 ASC...

Страница 36: ...iver only as broadcast command doesn t answer switches on video output driver only for the instrument with the address XX and switches off for all other instruments in the bus system User text AAox AA...

Страница 37: ...300 to 2000 C 3 875 380 3 875 390 3 882 380 3 882 390 MB 25L 350 to 2500 C 3 875 400 3 875 410 3 882 400 3 882 410 MB 30L 300 to 3000 C 3 875 470 Ordering notes When ordering please select one focusab...

Страница 38: ...C 1 A 3 852 550 Power supply NG 2D as NG 0D additionally with 2 limit switches not for US sale 3 890 640 LED digital display DA 4000 N 3 890 650 LED digital display DA 4000 with 2 limit switches 3 890...

Страница 39: ...8 Double storage 25 E Electrical connection 6 Electrical Installation 15 Electromagnetic requirements 15 Emissivity 23 31 ENT 21 Error Status 26 ESC 21 Exposure Time 24 Extended data protocol 36 Exter...

Страница 40: ...ace 35 S Safety 5 Scanner 26 31 35 Scope of Delivery 9 Serial interface 21 Service 7 Settings 23 Shield 15 Sighting 18 Single storage 24 Software InfraWin 27 Storage 8 Subrange 25 Switch contact 16 T...

Отзывы: