12.1 

Reference numbers instruments 

 

IS 210 

IGA 210 

 

650 to 1800°C 

(MB 18) 

800 to 2500°C 

(MB 25) 

300 to 1300°C 

(MB 13L) 

350 to 1800°C 

(MB 18L) 

Optics 300 

3 819 860 

3 819 890 

Optics 350 

3 819 870 

Optics 500 

3 819 880 

Optics 600 

3 819 740 

3 819 770 

3 819 800 

3 819 830 

Optics 1000 

3 819 750 

3 819 780 

3 819 810 

3 819 840 

Optics 1500 

3 819 760 

3 819 790 

3 819 820 

3 819 850 

 
 

12.2 

Reference numbers Accessories 

3 821 750 

Connection cable, 2 m 

3 821 760 

Connection cable, 5 m 

3 821 770 

Connection cable, 10 m 

3 821 780 

Connection cable, 15 m 

3 821 790 

Connection cable, 20 m 

3 821 800 

Connection cable, 25 m 

3 821 810 

Connection cable, 30 m 

 
3 826 500 

Portable battery driven setup device HT 6000 

3 821 600 

Connecting cable to HT 6000 

3 826 660 

USB a adjustment software 

InfraWin

 

3 890 640 

Digital display DA 4000-N for 2-wire devices power supply 

3 890 650 

Digital display DA 4000 for 2-wire devices power supply and 2 limit switches 

3 852 290 

Power supply NG DC; 100 to 240 V AC 

 24 V DC, 1 A 

3 837 360 

Water cooling jacket with integrated air purge  

3 835 320 

Air purge unit 

3 834 350 

Mounting angle, adjustable 

3 834 360 

Mounting angle, fixed 

 
 

Содержание IGA 210

Страница 1: ...IS 210 IGA 210 IMPAC Pyrometer Proven Quality Operation Manual Betriebsanleitung...

Страница 2: ...a USB adapter onto a PC 6 3 4 Connection to the portable parametrizing device HT 6000 7 4 Mechanical Installation accessories 7 5 Optics 7 6 Alignment with the LED targeting light 8 7 Parameter Settin...

Страница 3: ...s that arise from the use of any exam ples or processes mentioned in this manual or in case the content of this document should be incomplete or incorrect LumaSense Technologies reserves the right to...

Страница 4: ...peratures 75 C the output signal is set to approx 3 9 mA Load max 700 at 24 V power supply 400 18 V 1000 30 V Service interface for parameter programming with portable setup device HT 6000 or via USB...

Страница 5: ...dditional devices operating with this mains voltage e g transformers Touching mains voltage can be fatal An incorrect connection and mounting can cause serious health or material damages Only qualifie...

Страница 6: ...corder Digital display 230 V 4 20 mA white brown Schirm schwarz 24 V DC Power supply green yellow Power supply for LED targeting light White 24 V Pin 1 Brown 0 V Pin 2 Black Shield Green LED Pin 5 Yel...

Страница 7: ...least as big as the spot size of the pyrometer in the meas uring distance The following drawings show the pyrometer s spot sizes M in different measuring distances a The spot size M in a distance of a...

Страница 8: ...ch are different from the nominal distance of the selected optics may be calculated using the following formula D D M a a M 2 2 D D M a a M 1 1 6 Alignment with the LED targeting light For exact measu...

Страница 9: ...r the two spectral ranges of the in struments are listed in the emissivity table below The tolerance of the emissivity values for each material is mainly dependent on the surface conditions Rough surf...

Страница 10: ...until a new hot object appears in the measuring beam The temperature which has to be recognized as hot is defined by the low limit of the adjusted sub range The stored maximum value will be deleted wh...

Страница 11: ...surement curves Subsequent analysis graphically or in table form for print out or export Spot size calculator to calculate spot sizes in any distances 9 Transport packaging storage With faulty shippin...

Страница 12: ...suring distance see 5 Emissivity set too high Set lower correct emissivity corresponding to the material see 7 2 Lens contaminated Clean lens carefully see 10 2 Temperature indication too high Emissiv...

Страница 13: ...60 Connection cable 5 m 3 821 770 Connection cable 10 m 3 821 780 Connection cable 15 m 3 821 790 Connection cable 20 m 3 821 800 Connection cable 25 m 3 821 810 Connection cable 30 m 3 826 500 Portab...

Отзывы: