luft XC250 Скачать руководство пользователя страница 13

12

Manual XC250

EN

Use the SmartGraph3 PC software to carry out a detailed analysis
and visualisation of your measured results. Only by employing
this PC software can all options of the measuring device for
visualization and functioning be utilized (e.g. data export into an
Excel/PDF file or data output in form of a printout). 

Installation conditions

Ensure that the following minimum requirements for installing the
SmartGraph3 PC software are fulfilled:

• Supported operating systems (32 or 64 bit version):

– Windows XP from service pack 3

– Windows  Vista

– Windows  7

– Windows  8

• Software requirements:

– Microsoft .NET Framework (is automatically installed

during the software installation, where applicable)

• Hardware requirements:

– Processor speed: min. 1.6 GHz

– USB  connection

– 2 GB RAM, minimum

– 1 GB hard disk space, minimum

Installing the PC software

1. Download the current PC software from the Internet. To do

so, visit the website www.smartgraph3.de/download.

2. Double-click the downloaded file.

3. Follow the instructions of the installation wizard.

Starting the PC software

1. Start the SmartGraph3 software.

2. Switch on the device (see chapter Switch-on and

measurements) if necessary.

3. Connect the device to your PC via the USB connection cable

provided in the scope of delivery. After a few seconds (up to
one minute) the device is automatically detected and added
to the device list in the SmartGraph3 software.

Information about using the PC software is provided in the online
help.

The accurate functionality of the device was tested during
production a number of times. However, if functionality faults do
occur, then check the device according to the following list.

The device does not switch on:

• Check the loading status of the batteries. Change the

batteries when the message 

Batt lo

 is displayed upon

switch-on.

• Check that the batteries are properly positioned. Check the

polarity is correct.

• Never carry out an electrical check yourself; instead, contact

your Lufft

®

 customer service.

PC software

Errors and faults

Содержание XC250

Страница 1: ...p p p p p pou ou ou ou ou ou ou u ou ou ou ur r r r r r r r r r la la la la la la la la la la p p p p p p p p p p pr r r r r r r r r r ci ci ci ci ci ci ci ci ci cisi si si si si si si si si ion on on...

Страница 2: ...results Lufft Warranty The warranty is for 12 months Damages caused by incorrect use by untrained people or startup by unauthorised people are excluded from the warranty The device complies with the...

Страница 3: ...urface temperature of the measuring object and the dew point temperature within the measurement environment A minimum maximum and average function is available for the direct analysis of the measured...

Страница 4: ...Technical data Parameter Value Air temperature NTC Measuring range 20 to 50 C Tolerance 0 2 C 0 to 40 C otherwise 0 4 C Resolution 0 1 C Object temperature Pyrosensor Measuring range 70 to 380 C Toler...

Страница 5: ...Personnel qualifications People who use this device must have read and understood the operating manual especially the Safety chapter For maintenance or repair work which requires the housing to be ope...

Страница 6: ...bag to transport the device safely Storage When the device is not being used observe the following storage conditions dry protected from dust and direct sunlight with a plastic cover to protect it fr...

Страница 7: ...device is ready for operation The displayed units are based on the settings of the last utilization 4 Select the desired measuring mode 5 Point the device at the area to be measured The measured value...

Страница 8: ...measured value display 18 indicates either the humidity or the dew point To set the unit see Humidity display configuration on page 10 IR DP mode Risk from laser radiation Class 2 laser radiation Las...

Страница 9: ...l 2 2 Confirm with the OK button 12 CAL1 IR mode Specifying the temperature offset value range 10 to 10 C or 18 to 18 F Set the degree of emission value range 0 1 to 1 0 1 Enter the temperature offset...

Страница 10: ...e more the surface temperature drops the faster increases the repetition frequency of the acoustic and visual signals Maximum repetition frequency is triggered when reaching the lower alarm limit TdP...

Страница 11: ...values cannot be saved on the device itself In order to save measured values the device has to be connected to a PC via a USB cable using the SmartGraph software 1 Briefly press the OK button 12 The...

Страница 12: ...adiate Many organic materials and surfaces have a degree of emission of approx 0 95 Metal surfaces or shiny materials have a lower degree of emission and therefore only yield inaccurate measured value...

Страница 13: ...isit the website www smartgraph3 de download 2 Double click the downloaded file 3 Follow the instructions of the installation wizard Starting the PC software 1 Start the SmartGraph3 software 2 Switch...

Страница 14: ...il of 27th January 2003 concerning old electrical and electronic equipment After the end of its use please dispose of this device in a manner appropriate to the relevant legal requirements In the Euro...

Страница 15: ...820 E Mason St A Santa Barbara CA 93103 Tel 01 919 556 0818 Fax 01 805 845 4275 E Mail sales lufftusainc com www lufft com Lufft China Shanghai Of ce Lufft Shanghai Measurement Control Technology Co...

Отзывы: