luft XC250 Скачать руководство пользователя страница 11

10

Manual XC250

EN

Humidity display configuration

The humidity can be displayed in % RH, g/m

3

, g/kg and gr/lb, and

the dew point temperature in dp °C and dp °F.

1. Press the down key (11) until the desired unit is displayed.

– The humidity or dew point temperature will be displayed in

the selected unit in the lower measured value display (18).

– The unit (19) will be indicated on the display (1).

Measuring mode

1. Press the keys Right/back (10) or Left/menu (13) until the

desired measuring mode is displayed.

– The selected measuring mode (15) will be indicated on the

display (1).

The device comes with the following measuring modes:

Holding the measured value

1. Set the measuring mode to HOLD.

– The current measured value will be held and displayed.

– The device will hold this value until the measured values

are set back or the device is switched off.

Resetting the measured values

1. Press the OK button (12) for approx. 2 seconds.

– All previously stored measured values of the measuring

modes AVG, MIN, MAX and HOLD will be set back.

– All measured values are then determined anew based on

the measurement proceeding in the background.

Measured value storage

Please note that measured values cannot be saved on the device
itself. In order to save measured values, the device has to be
connected to a PC via a USB cable using the SmartGraph
software.

1. Briefly press the OK button (12).

– The displayed measured value will be saved in the

software.

Further information can be gathered from the help text of the
SmartGraph3 software.

Operating 
mode

Unit

Description

TH

g/m

3

Absolute humidity in g/m

3

g/kg

Mixing ratio in g/kg

gr/lb

Mixing ratio in gr/lb

dp °C

Dew point temperature in °C

dp °F

Dew point temperature in °F

% RH

Relative humidity in per cent

IR

g/m

3

Absolute humidity in g/m

3

g/kg

Mixing ratio in g/kg

gr/lb

Mixing ratio in gr/lb

dp °C

Dew point temperature in °C

dp °F

Dew point temperature in °F

% RH

Relative humidity in per cent

IR DP

dp °C

Dew point temperature in °C

dp °F

Dew point temperature in °F

g/m

3

g/kg gr/lb dp °C °F % rH

pp

19

Measuring 
mode

Description

TH

The device shows the air temperature and humidity (like a 
thermohygrometer).

IR

The device shows the surface temperature (like a 
pyrometer).

IR DP

The device shows both dew point and surface temperature 
(combination of thermohygrometer and pyrometer).

ACT

Measured value in real time

AVG

Average value of measurements since switch-on

MIN

Minimum measured value

MAX

Maximum measured value

HOLD

Measured value will be held

TH
HOLD

%WT

CM

m/s

ppm °F °C

IR

MAX

DP

MIN

AVG

CFG
ACT

15

Содержание XC250

Страница 1: ...p p p p p pou ou ou ou ou ou ou u ou ou ou ur r r r r r r r r r la la la la la la la la la la p p p p p p p p p p pr r r r r r r r r r ci ci ci ci ci ci ci ci ci cisi si si si si si si si si ion on on...

Страница 2: ...results Lufft Warranty The warranty is for 12 months Damages caused by incorrect use by untrained people or startup by unauthorised people are excluded from the warranty The device complies with the...

Страница 3: ...urface temperature of the measuring object and the dew point temperature within the measurement environment A minimum maximum and average function is available for the direct analysis of the measured...

Страница 4: ...Technical data Parameter Value Air temperature NTC Measuring range 20 to 50 C Tolerance 0 2 C 0 to 40 C otherwise 0 4 C Resolution 0 1 C Object temperature Pyrosensor Measuring range 70 to 380 C Toler...

Страница 5: ...Personnel qualifications People who use this device must have read and understood the operating manual especially the Safety chapter For maintenance or repair work which requires the housing to be ope...

Страница 6: ...bag to transport the device safely Storage When the device is not being used observe the following storage conditions dry protected from dust and direct sunlight with a plastic cover to protect it fr...

Страница 7: ...device is ready for operation The displayed units are based on the settings of the last utilization 4 Select the desired measuring mode 5 Point the device at the area to be measured The measured value...

Страница 8: ...measured value display 18 indicates either the humidity or the dew point To set the unit see Humidity display configuration on page 10 IR DP mode Risk from laser radiation Class 2 laser radiation Las...

Страница 9: ...l 2 2 Confirm with the OK button 12 CAL1 IR mode Specifying the temperature offset value range 10 to 10 C or 18 to 18 F Set the degree of emission value range 0 1 to 1 0 1 Enter the temperature offset...

Страница 10: ...e more the surface temperature drops the faster increases the repetition frequency of the acoustic and visual signals Maximum repetition frequency is triggered when reaching the lower alarm limit TdP...

Страница 11: ...values cannot be saved on the device itself In order to save measured values the device has to be connected to a PC via a USB cable using the SmartGraph software 1 Briefly press the OK button 12 The...

Страница 12: ...adiate Many organic materials and surfaces have a degree of emission of approx 0 95 Metal surfaces or shiny materials have a lower degree of emission and therefore only yield inaccurate measured value...

Страница 13: ...isit the website www smartgraph3 de download 2 Double click the downloaded file 3 Follow the instructions of the installation wizard Starting the PC software 1 Start the SmartGraph3 software 2 Switch...

Страница 14: ...il of 27th January 2003 concerning old electrical and electronic equipment After the end of its use please dispose of this device in a manner appropriate to the relevant legal requirements In the Euro...

Страница 15: ...820 E Mason St A Santa Barbara CA 93103 Tel 01 919 556 0818 Fax 01 805 845 4275 E Mail sales lufftusainc com www lufft com Lufft China Shanghai Of ce Lufft Shanghai Measurement Control Technology Co...

Отзывы: