background image

 5

LSL160

Horizontal use of LSL160

• Set up the unit on a surface that is as level as possible or fasten it to a  tripod.
• Turn the transport lock (G) in the arrow’s “Unlock”       direction to its limit. This releases the 

locking mechanism that protects the pendulum during transport.

• Press the On/Off button (A).
• Within its range of +/- 3,5°, the unit will level itself automatically and the prism head will 

begin to turn.

• The speed of rotation can be changed with the selector button (B), H = 600 RPM, M = 400 

RPM, L = 200 RPM.

Vertical use of LSL160

• Turn the transport lock (G) in the arrow’s “Lock”      direction to its limit.
• Hook the vertical/wall bracket into its receptacle (O). To do this, the locking lever (L) must 

be in its lower position and the bracket must latch audibly. To release the bracket, press the 
locking lever (L) down.

• Align the unit with the adjustment foot (J) as indicated by the vertical spirit level (F).
• Press the On/Off button (A). The prism head will begin to rotate.
• The speed of rotation can be changed with the selector button (B), H = 600 RPM, M = 400 

RPM, L = 200 RPM.

Note:

 Always unlock the transport lock when the LSL160 is being used for horizontal 

levelling by turning the transport lock to its “Unlock”        position. If the unit is currently 
outside of its automatic levelling range (> 3,5°) , a warning signal will sound and the 
prism head will not rotate. The unit must then be placed on a surface which is closer to 
level. When in  vertical use, the unit does 

not

 level itself automatically.

Содержание LSL160

Страница 1: ...Self Levelling Rotary Laser Detector LSL160 User Guide...

Страница 2: ...ialist workshop Calibration by yourself is only approximate and the accuracy of the calibration will depend on the care with which you proceed Warranty The warranty period is two years from the date o...

Страница 3: ...thread for tripod J Adjustable foot K Vertical base wall mount L Locking lever M Charger socket DC 6 V N Adjustable foot receptacle O Vertical wall bracket receptacle P Operating Battery display Q Ch...

Страница 4: ...chover precision range free hand range 11 LCD indicator rear side 12 LCD indicator SensoLite is able to detect the laser beam up to 200m from laser Move the SensoLite up and down through the laser bea...

Страница 5: ...ts receptacle O To do this the locking lever L must be in its lower position and the bracket must latch audibly To release the bracket press the locking lever L down Align the unit with the adjustment...

Страница 6: ...th the selector button B H 600 RPM M 400 RPM L 200 RPM Adjust the unit to the desired angle Slope angle can be set precisely and quickly with the aid of the optional tilt plate Part No LTP1 Important...

Страница 7: ...xchanged or recharged The device can also be operated with standard alkaline batteries 6 x type AA Insert the batteries as shown by the installation symbols Ensure the polarity is correct Insertion of...

Страница 8: ...EN60825 1 2007 10 Laser output rating 1 mW Rechargeable Batt batt operating time approx 20 h 45 h 6 x type AA Battery recharging time approx 14 h Working temperature range 10 C 40 C Protection class I...

Страница 9: ...one of the sides is towards the wall or post 4 Mark the level point on the wall or post and label this point C 5 Rotate the Laser on the surface or Tripod 180 so that the other side is towards the wa...

Страница 10: ...eet ALBURY N S W 2640 Australia GUARANTEE This product is guaranteed against any defect in material or workmanship for two years Damage caused by abuse improper use or excessive wear is not covered by...