Chapter 10 Communication 

Response:

 

‘$’_<ID>

5

_‚M’_<channel>

5

_<value>

5

 CR 

<ID>

5

 

Device address (5-point decimal with leading noughts)

 

<channel>

5

  Indicates the channel number (5-point decimal with leading noughts) 

<value>

5

 

Measurement value (5-point decimal with leading noughts); a value scaled to 0 
– 65520d. From 65521d – 65535d various error codes are defined. 

Example:

 

Request: 

&_12289_M_00601 

With this request, channel 601 of the device with address 12289 (VS2k-UMB with the device 
ID 0001) is polled. 

Response:  $_12289_M_00601_03456 

With the scaling for visibility the following calculation then results: 

0d 

 

corresponds to 0 metres 

65520d 

corresponds to 32760 metres 

03456d 

corresponds to 32760 / 65520 * 03456 = 1728 metres 

10.3  Channel assignment for data requests 

The following channel assignment is valid for online data request in binary protocol. In the 
ASCII protocol all channels are transmitted in the mapping standard. 

Channel 

Data type 

Measurement unit 

Measurement rante 

Description 

Current  Average 

Visibility 

600 

650 

float 

in metres 

10 

– 1000 Meter 

  

601 

651 

float 

in metres 

10 

– 2000 Meter 

602 

652 

float 

in kilometres 

0.01 

– 1.000 km 

603 

653 

float 

in kilometres 

0.01 

– 2.000 km 

604 

654 

float 

in feet 

32 

– 3000 feet 

605 

655 

float 

in feet 

32 

– 6500 feet 

606 

656 

float 

in miles 

0.006 

– 0.600 miles 

607 

657 

float 

in miles 

0.006 

– 1.200 miles 

608 

658 

unsigned 

short 

in the mapping 
standard 

20 

– 4000 

609 

659 

float 

10 

– 20000 

610 

660 

float 

km 

0.01 

– 20.00 

611 

661 

float 

ft 

32 

– 65000 ft 

612 

662 

float 

miles 

0.006 

– 12.400 miles 

Ambient temperature 

100 

150 

float 

in °C 

-40 - +80 °C 

  

101 

151 

in °F 

-40 - +176 °F 

102 

152 

unsigned 

short 

in the mapping 
standard 

  

Service 

4000 

--- 

unsigned char  logical 

0 - 100.255 

Pollution degree sender 

4001 

--- 

unsigned char  logical 

0 - 100.255 

Pollution degree receiver 

Содержание VS20k-UMB

Страница 1: ......

Страница 2: ...5 Installation 7 6 Connections 8 6 1 Screw in connector 8 6 2 Power supply 8 6 3 RS485 interface 8 6 4 Current output 8 7 Commissioning 9 8 Configuration 9 8 1 Factory settings 9 8 2 Configuration wit...

Страница 3: ...Channel assignment for data requests 13 10 4 Mapping standard 14 11 Technical Data 15 11 1 Visibility 15 11 2 Storage conditions 15 11 3 Operating conditions 15 11 4 Electrical Data 15 11 5 Interfaces...

Страница 4: ...d lamp systems Please observe the following safety instructions Do not look into the beam directly An exposure of more than 500s can lead to damage to the eye Avert your eyes for at least 60s after a...

Страница 5: ...converter ISOCON UMB 8160 UISO Power supply 24V 4A 8366 USV1 Surge protection 8379 USP Calibration kit 8366 UKAL2 3 3 Spare parts Connection cable 10 m 8366 UKAB10 Connection cable 20 m 8370 UKAB20 3...

Страница 6: ...the 42 forward scattering principle1 The particles in the field of measurement e g fog droplets scatter the infrared light emitted by the transmitter The receiver measures the rate of scattered light...

Страница 7: ...VS20k UMB Make sure that a distance of 2 m 6 5 ft in front of the measurement aperture is free of any kind of objects masts trees grass bushes etc Installation sketch WARNING Only approved and tested...

Страница 8: ...manently damaged You may risk an electric shock 6 2 Power supply The VS2k UMB VS20k UMB is powered by 24VDC The power supply unit must be approved for operation with equipment of protection class III...

Страница 9: ...ngs The VS2k UMB VS20k UMB is supplied with the following settings Device ID 1 Baud rate 19200 RS485 protocol UMB binary Current output VS2k UMB 4 20 mA corresponding to 0 2000 m linear Border contras...

Страница 10: ...al will show you an example of an online data request For more information about the protocol please download the document UMB Protocol on www lufft de 10 1 1 Framing Der Daten Frame ist wie folgt auf...

Страница 11: ...device ID the following address will result 3001h 12289d 10 1 4 Example of a binary protocol request If for example a visibility sensor with the device ID serial number 0001 is to be polled from a PC...

Страница 12: ...mode Start value FFFFh Warning In contrast to earlier Lufft protocols in this case the start value for CRC calculations is not 0h but FFFFh according to CCITT Further information can be found in the...

Страница 13: ...The following channel assignment is valid for online data request in binary protocol In the ASCII protocol all channels are transmitted in the mapping standard Channel Data type Measurement unit Meas...

Страница 14: ...ments are averaged over the configured time period 10 4 Mapping standard Mapping standard Visibility value range 0 65520 0 32760 m 0 32 76 km 0 107480 315 feet 0 20 3561203 miles Ambient temperature v...

Страница 15: ...de packaging 11 3 Operating conditions Permissible operating temperature 40 C 60 C 40 F 140 F Permissible rel humidity 0 100 r H 11 4 Electrical Data Voltage supply 20 30 VDC typical 24 VDC Current co...

Страница 16: ...ng on resetting and start of the calibration must be at least 90 s 13 Service and maintenance In order to have the instrument work smoothly we suggest to regularly carry out the following checks and m...

Страница 17: ...t must not be disposed of as household waste For environmentally sound recycling and the disposal of your waste equipment please contact a certified electronic waste disposal company 15 Manufacturer F...

Страница 18: ......

Отзывы: