20
CHAPTER 2. GETTING STARTED
• If datalogging in Mode 2 and a log event has been initiated, the button is used to accept
the current location ID.
Long Press (press and release after one beep):
• Currently has no effect by default.
Extra-Long Press (press and release after two beeps):
• Currently has no effect by default.
2.7 RATE Mode Operation
In RATE mode, the current count/exposure rate will be displayed. The maximum displayable
value, regardless of units, is 999 k.
If an alarm is not in progress, a long press of the ON/ACK button will reset the averaged rate
before releasing the button. The Reset feature must be enabled through Lumic 2.0 Calibra-
tion software and will be disabled when Sigma Audio is enabled.
A short press of the UNITS button will switch the displayed value between the Primary and
Secondary Units.
A short press of the ON/ACK button will cycle through the “click” audio volume levels. If
dual level audio is disabled, a short press of the ON/ACK button will toggle audio between
Off and On. If dual level audio is enabled, a short press of the ON/ACK button will toggle
the audio between "Hi, LO, and OFF". When Sigma Audio is enabled, a short press of the
ON/ACK button will toggle the Sigma Audio volume levels.
If an alarm condition is present, a short press of the ON/ACK button will acknowledge and
turn off the alarm audio. Under an alarm condition, the ALARM display indicator will be
activated. There are two user settable alarms for both the primary and secondary units. If
both alarms for a particular unit are set, the first alarm will activate beeping alarm audio and
a flashing ALARM display indicator; If only one alarm is set or the second alarm is triggered,
both the alarm audio and the ALARM display indicator are continuous. Alarms are non-
latching in RATE mode.
When Sigma Audio is enabled, and an alarm condition is not present, a long press of the
ON/ACK button will reset the Sigma Audio alarm level. The Sigma count can only be reset in
RATE mode. If sigma audio and device rate reset are both enabled, the device rate reset will
automatically be disabled.
If other detectors are available, a short press of the DETECTOR will switch between available
detectors as evidenced by the DET LEDs.
Ludlum Measurements, Inc.
Содержание 25009185
Страница 2: ......
Страница 4: ......
Страница 6: ......
Страница 7: ......
Страница 8: ......
Страница 12: ......
Страница 14: ......
Страница 32: ......
Страница 35: ...29 Weight 0 7 kg 1 6 lb excluding detectors and clips December 2021 ...
Страница 36: ......
Страница 56: ......
Страница 62: ......
Страница 72: ......
Страница 74: ......
Страница 78: ......