background image

TECHNICAL SUPPORT HOT LINE 

1-800-526-0725 

HOURS: 7:30-3:30 

21112 72nd Ave. So.      Kent, Washington  98032 

LUCKS FOOD EQUIPMENT COMPANY 

 

® 

TO: 

BOB VAN WYCK 

Technical Support Manager 

Burner Pilot Tube 

Replacement 

SUBJECT: 

FROM: 

 

Service Providers 

 

0102-1 

BULLETIN No: 

DATE: 

Feb 1, 2001 

MESSAGE: 

The purpose of this bulletin is to inform our service providers of a 

Burner Pilot Tube Replacement Kit 

which is available to be used 

on all ovens, manufactured after 1997, that are experiencing failure 
due to carbon fouling of the ignitor. 
 
See the attached information for diagnoses procedure and 

 

conversion instructions. 

Products Affected: 

Number of attachments: 

Rack Ovens 

7 pages 

Содержание 115517

Страница 1: ...ders 0102 1 BULLETIN No DATE Feb 1 2001 MESSAGE The purpose of this bulletin is to inform our service providers of a Burner Pilot Tube Replacement Kit which is available to be used on all ovens manufa...

Страница 2: ...Lucks Rack oven that has an Eclipse Thermjet burner and is experiencing flame failure should be diagnosed as follows 1 Is the flame failure due to a failure to ignite the pilot gas 2 Does the ignitor...

Страница 3: ...Technical Support 800 526 0725 or 800 824 0696 Burner Pilot Tube Field Retrofit Kit Number 115517 Parts Supplied In Kit Description Quantity Lucks Part Number Instructions this document 1 Ea 117950 Fi...

Страница 4: ...o form on the ignitor This field retrofit is to identify and replace the burner pilot tube to reduce the pilot flame BTU s It is important to note that carbon fouling can also be caused by air fuel ra...

Страница 5: ...Company Technical Support 800 526 0725 or 800 824 0696 B Identify and remove the existing burner pilot tube and fittings 1 Review the detailed picture below Remove the items identified by the arrows...

Страница 6: ...h and shape of the new alum pilot tube The new pilot tube is 8 inches long and should be shaped as shown in detail 3 below If not you may use the detail below as a template to shape the tube Be sure n...

Страница 7: ...mer are powered D 10 seconds later the pilot gas valve and transformer loose power and the Honeywell s flame failure buzzer sounds 4 If all went well with steps A D above then turn on the manual gas v...

Страница 8: ...other times prior approval must be obtained from the Lucks Company to cut security seals or the equipment warranty may be voided AIR ADJUSTMENT The air shutter is located inline with the flex tubing c...