C-26
MAX Administration Guide
Machine Interface Format (MIF)
ROUTE
.Idle=None,Call
.Dial=Terminal,DTR Active,RS-366 Ext1,RS-366 Ext2,V.25bis,
V.25bis-C,X.21 Ext1,X.21 Ext2,X.21 Ext1-P
.Answer=Auto,DTR Active,DTR+Ring,V.25bis,V.25bis-C,Terminal,
X.21,P-Tel Man,None
.Clear=DTR Inactive,DTR Active,RTS Inactive,RTS Active,
Terminal
.Term Timing=Yes,No
.RS-366 Esc=*,#,5,6,7,9,0,00
.Early CD=Answer,Originate,Both,No
.DS0 Min Rst=Monthly,Daily,Off
.Max DS0 Mins=
number
.Max Call Mins=
number
Note:
•
spp.PORT...
s = 1 or any slot in which a serial host expansion module is installed.
pp = 01 through last serial host port.
For example:
: LOAD 201.PORT.0
: SET 201.PORT.0.Port Name=Chicago #1
+ ERROR
: SET Port Name=Chicago #1
: SAVE 200.PORT.0
+ ERROR
: SAVE 201.PORT.0
:
ROUTE
s
00.ROUTE.
n
.Name=
text
.Active=Yes,No
.Dest=
text in dotted decimal format/subnet mask
.Gateway=
text in dotted decimal format
.Metric=
number
.Private=Yes,No
Note:
•
This type applies to the MAX equipped with the Ethernet module.
•
s00.ROUTE.n...
s = slot into which the Ethernet card is installed
n = 0 to 63
•
If n = 0, Name=Default and Dest=0.0.0.0/0