255-700-714R11.0
4-9
PacketStar
®
PSAX 1-Port Channelized OC-3/STM-1 CES Module User Guide
, Issue 1
Release 11.0.0
Chapter 4 Configuring the STM-1 Mode Ports and Channels Using the Console
Obtaining General Module Data and Accessing Ports and Channels
The Alarm Status field on the Equipment Configuration window is described
in Table 4-3.
SW #
Default:
N/A
Range: N/A
Format: Predefined
Displays the version of PSAX system software with which
the modules’ firmware was released. The software version is
encoded in the module firmware. Because not all modules
require firmware upgrades with every new PSAX system
software release, the software version that is displayed in
this window may be lower than the CPU system software
that is currently running on the PSAX system. See the most
recent Release Note document for the latest software and
firmware lineup information.
PEC
Default:
N/A
Range: N/A
Format: Predefined
Displays the product element code (PEC) used to identify
and order this type of module. The PEC is encoded in the
module bootloader.
Serial #
Default:
N/A
Range: N/A
Format: Predefined
Displays the unique serial number of the individual module.
The product serial number is encoded in the module firm-
ware.
For PSAX System Rel. 6.5.0 and later: 12-digit number in
the format,
YYVVDDnnnnnn
, where
YY
= year of manufac-
ture
VV
= vendor ID code (manufacturer and location)
DD
=
date code of manufacture (either month or week depending
on vendor preference)
nnnnnn
= sequential number, which
in conjunction with
YY, VV
, and
DD
, creates a unique num-
ber for each hardware component in the PSAX product line.
For existing products with the 10-digit serial number used
in Rel. 6.5.0 or later, this number is displayed with two pre-
ceding zeros.
For PSAX Rel. 6.3.0 and earlier: 10-digit number. For prod-
ucts with 12-digit serial numbers used in Rel 6.3.0 or earlier
systems, the first two digits (
YY
) are not displayed.
Table 4-2. Equipment Configuration Window Field Descriptions (Continued)
Field Name
Field Value
Description
Table 4-3. Module Alarm Status Descriptions on the Equipment Configuration Window
Alarm Status
Module Type
Affected
Description
NoAlarm
I/O and Server Indicates that no alarms have been detected for the module
in this slot.
WrongCardType
I/O and Server Indicates that one type of module was configured in this
slot in the chassis, but a now different module occupies this
slot.
LineFailed
All
Indicates that the module in this slot is no longer receiving
or transmitting signals because the line failed.
Содержание 23N12
Страница 175: ......
Страница 176: ...Copyright 2005 Lucent Technologies All rights reserved Part Number 569M2A11003D1...