Chapter 4 Configuring the STM-1 Mode Ports and Channels Using the Console
Viewing the Channelized STM-1 Statistics
4-62
255-700-714R11.0
PacketStar
®
PSAX 1-Port Channelized OC-3/STM-1 CES Module User Guide
, Issue 1
Release 11.0.0
Table 4-30. Channelized STM-1 SM/MM Virtual E1 Port Statistics Window Field Descriptions
Field Name
Field Value
Description
Errored Seconds
Default:
0
Range: 0–9999999999
Format: Numeric (sec)
Displays the number of errored seconds with at least one
of the following characteristics per second:
•
Path code violations
•
Controlled slip events
•
Detected alarm indication signal (AIS) defect
•
Presence of bipolar violations.
Severely Errored
Seconds
Default:
0
Range: 0–9999999999
Format: Numeric
Displays the number of severely errored seconds with at
least one of the following characteristics per second:
•
320 or more path code violation error events
•
Out-of-frame (OOF) defects
•
Detected AIS defect
•
A count of one-second intervals with framing error
events, an OOF defect, or a minimum of 1,544 line
code violations.
Severely Errored
Framing Seconds
Default:
0
Range: 0–9999999999
Format: Numeric
Displays the number of severely errored framing seconds
encountered by the virtual DS1 port in one of the previ-
ous 96, individual 15-minute intervals. A severely
errored framing second has one or more out-of-frame
defects or a detected AIS (alarm indication signal) defect.
Unavailable Sec-
onds
Default:
0
Range: 0–9999999999
Format: Numeric
The number of unavailable seconds encountered by the
virtual DS1 port in one of the previous 96 individual 15-
minute intervals. Unavailable seconds (UAS) are calcu-
lated by the number of seconds that the interface is
unavailable.
Controlled Slip
Seconds
Default:
0
Range: 0–9999999999
Format: Numeric
Displays a one-second interval containing one or more
controlled slips. The number of controlled slip seconds
encountered by DS1 in the previous 24-hour period.
Path Coding Vio-
lations
Default:
0
Range: 0–9999999999
Format: Numeric
Displays a frame synchronization bit error in the D4 and
E1-noCRC formats, or a CRC error in the ESF (Extended
Super Frame) and E1-CRC formats. The number of Path
Coding Violations encountered by DS1 in the previous
24-hour period.
Line Errored Sec-
onds
Default:
0
Range: 0–9999999999
Format: Numeric
Displays a second in which one or more Line Code Viola-
tion error events were detected. The number of Line
Errored Seconds encountered by DS1 in the previous
24-hour period.
Bursty Errored
Seconds
Default:
0
Range: 0–9999999999
Format: Numeric
Displays a second with fewer than 320 and more than 1
Path Coding Violation error events, no Severely Errored
Frame defects, and no detected incoming AIS defects.
The number of bursty errored seconds encountered by
DS1 in the previous 24-hour period.
Line Coding Vio-
lations
Default:
0
Range: 0–9999999999
Format: Numeric
Displays a bipolar violation or excessive zeroes error
event.
Содержание 23N12
Страница 175: ......
Страница 176: ...Copyright 2005 Lucent Technologies All rights reserved Part Number 569M2A11003D1...