255-700-714R11.0
4-37
PacketStar
®
PSAX 1-Port Channelized OC-3/STM-1 CES Module User Guide
, Issue 1
Release 11.0.0
Chapter 4 Configuring the STM-1 Mode Ports and Channels Using the Console
Configuring the 1+1 Protection Parameters
Reset APS/MSP Statistics
Sets all field values to
0
.
APS/MSP Commands (Left Panel)
Apply APS/MSP Command
Runs the command you selected in the APS Command or
MSP Command field.
Configuration Commands (Right Panel)
Apply APS/MSP Parameters
Applies the configuration values for both the primary and the
standby OC-3c APS or MSP modules.
Reset APS/MSP Display
Resets the fields to the last set of saved values.
Go Back to Port Configura-
tion
Redisplays the Port and Channel Configuration window.
Table 4-16. Channelized OC-3STM-1 APS/MSP Configuration Window Commands (Continued)
Command
Function
Table 4-17. Channelized STM-1 SM MSP Configuration Window Field Descriptions
Field Name
Field Value
Description
MSP Statistics Panel
Working Port SF
Dur
Default:
0
Range: 0–99999999
Format: Numeric
(sec)
Specifies the amount of time in seconds that the working
port has had a failed signal (SF) above the selected thresh-
old bit error rate. This value updates dynamically as traffic
passes through the module.
Working Port SD
Dur
Default:
0
Range: 0–99999999
Format: Numeric
(sec)
Specifies the amount of time in seconds that the working
port has had a degraded signal (SD) above the selected
threshold bit error rate. This value updates dynamically as
traffic passes through the module.
Prot. Port SF
Duration
Default:
0
Range: 0–99999999
Format: Numeric
(sec)
Specifies the amount of time in seconds that the protec-
tion port has had a failed signal (SF) above the selected
threshold bit error rate. This value updates dynamically as
traffic passes through the module.
Prot. Port SD
Duration
Default:
0
Range: 0–99999999
Format: Numeric
(sec)
Specifies the amount of time in seconds that the protec-
tion port has had a degraded signal (SD) above the
selected threshold bit error rate. This value updates
dynamically as traffic passes through the module.
Switch Over
Counts
Default:
0
Range: 0–99999
Format: Numeric
(sec)
Specifies the number of times that switchover of active
status from one module to the other in the pair has
occurred. This value increments and is displayed as an
integer.
TX K1/K2
Default:
00/00
Range:
Format: Bytes dis-
played in hexadeci-
mal
Specifies for the transmit port the protocol used in the
MSP channel that carries the K1 and K2 bytes in the signal
in the protection line. The K1 byte is used to indicate a
request by a channel for a switch action. The K2 byte is
used to indicate the bridging actions performed at the LTE,
and the provisioned architecture and mode of operation
Содержание 23N12