Stinger® FS/Stinger FS+ Getting Started Guide
Preparing for the Installation
Verifying the hardware configuration
Figure 1-4. Front view of a Stinger FS+ chassis
The middle two slots in the front of the Stinger FS and Stinger FS+ (slots 8 and 9) are
reserved for the control modules; they cannot be used for line interface modules
(LIMs). Slots that are not occupied by modules must be masked with blank covers to
ensure proper air flow through the unit.
Verifying the chassis operating voltage of the chassis
All chassis designed with a fan tray that can be replaced from the front of the unit
and a warning label like the one shown in Figure 1-5 can be installed in a -48Vdc or
a -60Vdc environment.