Obtaining statistics about operations
Checking interface status
............................................................................................................................................................................................................................................................
363-217-018R9.8
Issue 1, August 2005
5 - 7
............................................................................................................................................................................................................................................................
Obtaining statistics about operations
Introduction
The
p h y s i c a l - s t a t i s t i c
subprofile enables you to check interface operations.
Physical-statistic profile example
Following are the
p h y s i c a l - s t a t i s t i c
parameters shown with sample settings for
an active interface:
[ i n A L - D M T - S T A T / { s h e l f - 1 s l o t - 3 4 } : p h y s i c a l - s t a t i s t i c ]
l i n e - u p - t i m e r = { 0 0 1 }
r x - s i g n a l - p r e s e n t = y e s
u p - d w n - c n t r = 3
s e l f - t e s t = p a s s e d
n o i s e - m a r g i n - d o w n = 6
a t t e n u a t i o n - d o w n = 5 6
o u t p u t - p o w e r - d o w n = 1 9
n o i s e - m a r g i n - u p = 5
a t t e n u a t i o n - u p = 4 1
o u t p u t - p o w e r - u p = 1 1
n e a r - e n d - f e c = 0
n e a r - e n d - c r c = 0
n e a r - e n d - h e c = 0
f a r - e n d - f e c = 1 0
f a r - e n d - c r c = 0
f a r - e n d - h e c = 0
r e c e i v e d - r s - b l c k s = 1 0 4 0 7 3
t r a n s m i t t e d - r s - b l o c k s = 4 1 6 7 7 2
i n c o m i n g - c e l l s = 9 2
o u t g o i n g - c e l l s = 1 0 0
Physical-statistic details
Parameter
Description
l i n e - u p - t i m e r
Indicates how long the interface has been up (days, hours, and
minutes in {
dd hh mm
} format). It is reset when a line is
initialized or when the setting of the
dev-line-state
parameter changes to port-up from any other state.
r x - s i g n a l - p r e s e n t
Indicates whether receiving (
y e s
) or not receiving (
n o
) signal
from the CPE.
u p - d o w n - c n t r
Indicates the number of times the link has changed from an
up
state to a
down
state since the module was last reset.
Содержание STGRCR-ELIM-AP-48
Страница 5: ...Contents v 363 217 018R9 8 Issue 1 August 2005 Built in self testing BIST 6 20 IN Index ...
Страница 6: ... Contents v i 363 217 018R9 8 Issue 1 August 2005 ...
Страница 8: ... List of Figures v i i i 363 217 018R9 8 Issue 1 August 2005 ...
Страница 12: ... About This Information Product x i i 363 217 018R9 8 Issue 1 July 2005 ...
Страница 42: ... Power level parameters Interface profile and power parameters 2 1 2 363 217 018R9 8 Issue 1 August 2005 ...
Страница 60: ... Configuring call control Configuring an ADSL Annex A LIM 3 1 8 363 217 018R9 8 Issue 1 August 2005 ...
Страница 66: ... Examples for configuration of ADSL2 line codes Configuration Examples 4 6 363 217 018R9 8 Issue 1 August 2005 ...
Страница 98: ... Built in self testing BIST Line testing 6 2 2 363 217 018R9 8 Issue 1 August 2005 ...