3-84
Issue 5
May 1997
363-208-010
Cabling, Wiring, and Assembly
DSX-1 Metallic Feeder for
FiberReach and MSDT
General
This application is for a metallic DS-1 interface between the MDS shelf containing
the DT server (for example, SPQ
®
808,
SPQ809, or SPQ810) and the DSX-1
interface. The DSX-1 cross-connect panel could be cabled to a DDM-2000
FiberReach Wideband Shelf, FITL HDOS shelf, or a T1 Carrier Office Repeater
Bay, etc.
Connections for MDS to DSX-1
This procedure consists of installing mating cables to the bay cable which is
normally part of the transmission path between the MDS and HDOS shelves and
terminating their other end at the DSX-1.
The procedure below is for one shelf. Up to eight shelves can be connected for
FITL DT server connections.
Step 1:
Install the MDS/HDOS transmission cable assembly, ED7C723-35,
Group 17 by connecting the cable to the MDS danglers (J101 through
J104 or J201 through J204) associated with the shelf populated with
FITL DT server(s).
Step 2:
Mate a pair of DSX-1 interface cables (ED7C723-35, Group 19, 20, 21,
or 22, for example) for each transmit (OUT) and receive (IN) arm of the
Group 17 cable assembly's P191 or P192 connectors. Stamp each con-
nector with a designation which agrees with its mating connector (i.e.
J191-OUT mating to P191-OUT). Identify the butt cut end of the cable
with a similar stamp or label.
NOTE
:
The ED7C723-35 DSX-1 interface cable is available in four
lengths.
Step 3:
Find a convenient place on the frame, scrape the paint, and attach the
lug from the drain wire to the frame with a 12-24 panel mounting screw
(Comcode 801486341).
Length (ft.)
Equipment Code
Comcode
30.0
ED7C723-35, Group 19
601845472
50.0
ED7C723-35, Group 20
601845480
100.0
ED7C723-35, Group 21
601845498
200.0
ED7C723-35, Group 22
601845506
Содержание SLC-2000 Access System Central Office Terminal
Страница 1: ...SLC 2000 Access System Customer Assembly Manual for RT Frames 363 208 010 Issue 5 May 1997...
Страница 4: ...This page is intentionally blank...
Страница 10: ...viii Issue 5 May 1997 Contents...
Страница 16: ...xiv Issue 5 May 1997 Tables...
Страница 24: ...1 ii Issue 5 May 1997 Contents General Information...
Страница 34: ...2 iv Issue 5 May 1997 Tables Installation Procedures 2 1 Dimensions for Figure 2 2 6...
Страница 66: ...3 viii Issue 5 May 1997 Contents Cabling Wiring and Assembly...