255-700-585
3-49
PacketStar
®
PSAX 3-Port DS3/E3 ATM Protection Module User Guide
, Issue 1
Release 10.0.0
Chapter 3 Configuring Ports and Channels Using the Console
Saving the Module Configuration
2
Select the
Save Configuration
command or press Ctrl+A.
Wait a few seconds while the system writes the values to the PSAX sys-
tem database. The system displays the following message while it is exe-
cuting this command:
Saving the equipment and connection information
Note:
In PSAX systems with redundant CPU
n
modules, the standby
CPU
n
module reboots every time you save the configuration on
the primary CPU
n
module. This event is a function of the SVC
retention feature and the result of saving the configuration
changes you have made.
When the save configuration function is completed, the system displays
an appropriate message as described in Table 3-14.
Figure 3-24. Save Configuration [Modified] (Before Saving)
Table 3-14. Messages Generated after the Save Configuration Process
When a PSAX
system is...
the system displays...
nonredundant
T-SaveConfiguration: saveConfigurationReasonCode=All-OK
redundant
T-SaveConfiguration: saveConfigurationReasonCode =
Expect2ndCPUCardFailedOrRemoved
*
The standby CPU
n
module is rebooted when the save command is issued.
After the standby CPU
n
module reboots, the system displays the following
message:
T-SaveConfiguration: saveConfigurationReason-
Code=FileTransferCompleted
*
This message indicates that while the standby CPU
n
module reboots after you select the
Save
Configuration
command, the standby CPU
n
module is temporarily unavailable.