CP not allowed - crs
....................................................................................................................................................................................................................................
CP not allowed - crs
The circuit pack does not support the cross-connection(s) currently
provisioned for the slot.
Alarm Data
Value/Meaning
Reported Alarm
Level(s)
Critical (CR), Minor (MN)
AID (type)
Slot
Date
month/day/year that condition was detected
Time
hour:minute:second that condition was detected
Probable Cause
FACTERM
Effect on
Service
CR = SA
MN = NSA
Alarm Entity
Type
EQPT
Description
CP not allowed - crs
Likely Cause
A circuit pack was inserted into a slot that was
already provisioned with cross-connections, and
those provisioned cross-connections are not
supported by the new circuit pack.
Visible
indication
Lighted
CR/MJ
or
MN/ABN
LED on SYSCTL
faceplate and a continuously lighted
FAULT
LED
on the affected circuit pack.
Action
Proceed to
Alarms, conditions, and error messages
....................................................................................................................................................................................................................................
3 - 1 2
Lucent Technologies
365-372-333 R2.1
Issue 4, June 2005