Procedure 5-24: Clear
″
inc. DS3 Cbit Mismatch
″
alarm
....................................................................................................................................................................................................................................
Overview
This procedure is used to clear an
inc. DS3 Cbit Mismatch
alarm
indicated by a lighted
CR/MJ
or
MN/ABN
LED on the SYSCTL
faceplate and reported as critical, major, minor, or Not Alarmed in the
WaveStar
®
CIT Alarm List.
Before you begin
Prior to performing this procedure:
1.
Refer to
and
in this chapter.
2.
Refer to
“Electrostatic discharge” (1-13)
in
Procedure
Complete the following steps to clear an
inc. DS3 Cbit
Mismatch
alarm.
............................................................................................................................................................
1
From the WaveStar
®
CIT System View, click the
Alarm List
button
and locate the
inc. DS3 Cbit Mismatch
alarm in the resulting alarm
list and note the corresponding AID.
............................................................................................................................................................
2
From the System View menu, select
View
→
Equipment
, expand the
group (GRP), highlight the alarmed port, and then click
Select
.
Result:
The View Equipment window opens.
............................................................................................................................................................
3
In the Transmission section on the window, locate and record the
provisioned signal format.
............................................................................................................................................................
4
From the System View, select
Configuration
→
Equipment
, expand
the group (GRP), highlight the desired port, and then click
Select
.
Trouble clearing procedures
....................................................................................................................................................................................................................................
365-372-333 R2.1
Issue 4, June 2005
Lucent Technologies
5 - 7 1