Procedure 5-23: Clear
″
inc. DS1
″
conditions/alarms
....................................................................................................................................................................................................................................
Overview
This procedure is used to clear the following
inc. DS1
alarms:
•
inc. (from DSX) DS1 AIS
•
inc. (from DSX) DS1 LOF
•
inc. (from DSX) DS1 LOS
•
inc. (from DSX) DS1 sig. failed
Refer
and
Chapter 3, “Alarms, conditions, and
for the possible alarm levels for the different alarms.
Before you begin
Prior to performing this procedure:
1.
Refer to
and
in this chapter.
2.
Refer to
“Electrostatic discharge” (1-13)
in
Procedure
Complete the following steps to clear an
inc. DS1
alarm.
............................................................................................................................................................
1
From the WaveStar
®
CIT System View, click the
Alarm List
button
and locate the
inc. DS1
alarm in the resulting alarm list.
............................................................................................................................................................
2
Determine the alarm level(s) for the active
inc. DS1
alarm(s) (for
example, MJ or MN). Clear the alarms in order of severity, MJ, MN,
and then Not Alarmed.
............................................................................................................................................................
3
Refer to the Probable Cause column in the alarm list, determine the
port affected by the
inc. DS1
alarm, and note the corresponding AID.
............................................................................................................................................................
4
Check cable connections between the access panel and the DSX panel
for faulty connections or damage and repair/replace as necessary.
............................................................................................................................................................
5
From the System View, click the
Alarm List
button and click
Refresh
.