MERLIN LEGEND Communications System Release 5.0
Feature Reference
555-650-110
Issue 1
June 1997
Features
Page 82
Basic Rate Interface (BRI)
Basic Rate Interface (BRI)
3
At a Glance
3
Users Affected
Telephone users, operators, digital data users
Reports Affected
System Information (
SysSet-up
), BRI Information
Modes
Key, Hybrid/PBX
Telephones
All (display support on MLX telephones only)
System Programming
800 NI-BRI Module
Specify 800 NI-BRI modules that provide primary, secondary,
and tertiary clock synchronization and source of clock
synchronization; also activate/deactivate clock:
●
LinesTrunks
→
More
→
ClockSync
Assign telephone numbers (SPID and DN) to BRI lines:
●
LinesTrunks
→
More
→
BRI
→
SPID/DN
→
SPID
→
Enter
→
DN
→
Enter
Specify BRI timer settings:
●
LinesTrunks
→
More
→
BRI
→
Timers
Maximums
BRI modules
5
Factory Settings
Systemwide Clock
Synchronization Source
Primary Clock
Clock
BRI
Service Profile Identifier
(SPID) assigned to BRI
line
Loop (not definable by system manager)
First port in service on an 800 NI-BRI module or first 100D
module in service in control unit
Active
0 digits
Directory Number (DN)
assigned to BRI line
0 digits
Timer and counter
thresholds for all BRI
ports in system
T200 Timer
T203 Timer
T303 Timer
T305 Timer
T308 Timer
1000 ms (range 500–5,000 ms, increments of 500 ms)
33 seconds (range 10–255 seconds, increments of 1 second)
4 seconds (range 2–10, increments of 1 second)
30 seconds (range 2–60, increments of 1 second)
4 seconds (range 2–10, increments of 1 second)