3-14
MAX TNT Hardware Installation Gulide
Installing a MAX TNT Chassis
Powering on a MAX TNT unit
Powering on a MAX TNT
unit
Note:
Before powering on an unconfigured MAX TNT unit, you must connect it to a
workstation. For instructions see “Connecting a workstation to the serial port” on page 3-11.
To power on your new MAX TNT unit:
1
Position yourself so that you can observe the lights on the back panel while you view the
monitor display.
2
Turn on the power to the unit. For ac power supplies, plugging in the power cord supplies
power. For dc power supplies, flip the power switch to the On (up) position.
After a few minutes, the terminal emulator displays the following messages. If the
messages do not appear, press Ctrl-L to refresh the screen. If they still do not appear,
verify that the terminal emulator is connected with a straight-through serial cable and is
using the settings listed in step 2 of “Connecting a workstation to the serial port” on
page 3-12.
*** TNT, unconfigured unit***
The system date is: Thu Aug 27 12:34:39 1998
If incorrect, please enter the proper value using this
command:
date yymmddhhmm
Please configure these profiles:
SYSTEM
IP-GLOBAL
IP-INTERFACE
LOG
SERIAL
for your operating environment.
TNT>
3
Check the PCMCIA flash-card file system to verify that the card and its contents have no
errors. Enter the Fsck command as shown in the following example:
admin>
fsck 1
ffs check in progress for card 1...
Dir 1 not in use
Dir 2 has magic, version 2, size 16, sequence 0xa
Using dir entry: 2, total data blocks: 0x40, directory size: 16
shelf-controller:(0xfe)
reg good 1228008 (0x12bce8) Sep 23 18:08
8t1-card:(0x00)
reg good 195368 (0x02fb28) Sep 23 18:08
4ether-card:(0x10)
reg good 176597 (0x02b1d5) Sep 23 18:08
48modem-card:(0x01)
reg good 690472 (0x0a8928) Sep 23 18:09
t3-card:(0x06)
reg good 224620 (0x036d6c) Sep 23 18:09