6-18
MAX 3000 Installation and Basic Configuration Guide
Quickstart
Configuring WAN lines
Figure 6-4. Incoming call routing using ISDN E1/PRI signaling
R2 signaling
Figure 6-5 illustrates incoming call routing using R2 signaling. The example shows two hunt
groups: one for digital calls and one for analog calls. Analog callers use the telephone number
555-1111 to call in and are routed to the digital modems in slot 7. Digital callers use the
telephone number 555-2222 and are routed to the MAX Ethernet module in slot 4.
Figure 6-5. Incoming call routing using R2 signaling
CH 1
CH 2
_
_
_
_
_
_
_
_
_
_
_
_
CH 31
CH 32
Digital modem card
(slot 7)
Ethernet module
(slot 4)
WAN
555-1111
555-1111
Net /E1 module
CH 1
CH 2
_
_
_
_
_
_
_
_
_
_
_
_
CH 31
CH 32
Digital modem card
(slot 7)
Ethernet module
(slot 4)
WAN
555-1111
555-2222
Net /E1 module