Line timing references
Proceed as follows to configure the line timing references in NE-B, NE-C and NE-D:
.................................................................................................................................................................................................
1
Start a remote login to NE-B.
To do that, enter the following:
•
The
TID
of NE-B as
NE Name
•
LambdaUnite(R) MSS
as
NE Type
•
OSI
as
Connection Type
.
Click
Graphical
.
Result:
All units of NE-B will be displayed.
.................................................................................................................................................................................................
2
In the
WaveStar
®
CIT
System View
, select
Configuration
→
Timing/Sync...
.
Result:
The
Synchronization Characteristics
window appears.
.................................................................................................................................................................................................
3
Select the
Line Reference 1
tab.
.................................................................................................................................................................................................
4
In the
Signal Quality
group box, select
AUTO
in the
Provisioned Quality Level
drop-down list box.
.................................................................................................................................................................................................
5
In the
Provisionable Settings
group box, select the priority in the
System Timing
Reference Priority
drop-down list box.
.................................................................................................................................................................................................
6
In the
Provisionable Settings
group box, select the
Assigned Port AID
of the port
that is connected to NE-A. To do this, click
Browse...
in order to open the
Select
Line Timing Port AID
window.
.................................................................................................................................................................................................
7
In the
Provisionable Settings
group box, select
Monitored
in the
Timing Port Mode
Monitoring
drop-down list box.
.................................................................................................................................................................................................
8
Select the
System Timing
tab, then the
System Timing
tab again.
.................................................................................................................................................................................................
9
In the
General Parameters
group box, set the
Wait To Restore
(WTR) time.
Network establishment and testing
Line timing test setup
.................................................................................................................................................................................................................................
365-374-187
Issue 1, December 2005
Lucent Technologies - Proprietary
See notice on first page
10-21