Alarm reporting tests
.................................................................................................................................................................................................................................
Overview
The tests described below verify that currently active alarms of the system are reported
to the
WaveStar
®
CIT, to the User Panel and to the rack alarm lamps that are located
at the rack top (front and rear). The tests include raise and clear behavior of the alarms
created.
Required equipment
Prior to performing this task, the following equipment must be available:
1.
WaveStar
®
CIT PC
2. CAT5 crossover LAN cable with RJ-45/RJ-45 connectors (see chapter 4,
4-48, “CIT connection (LAN crossed)” (p. 4-74)
3. ESD Wrist Strap.
Prerequisites
Prior to performing this task, you must have done the following:
1. Logged in to
WaveStar
®
CIT as Super User (see chapter 5, section
) if
WaveStar
®
CIT User Login has been
enabled during
WaveStar
®
CIT installation.
2. Logged in to the NE.
Minor alarm test
CAUTION
ESD hazard
Electronic components can be destroyed by electrostatic discharge.
Always observe the ESD instructions (cf.
“Electrostatic discharge” (p. 1-20)
Stand-alone test procedures
.................................................................................................................................................................................................................................
365-374-187
Issue 1, December 2005
Lucent Technologies - Proprietary
See notice on first page
8-3