Changing the NE name (TID)
.................................................................................................................................................................................................................................
Overview
This section provides a procedure for changing the NE name (TID).
Required equipment
Prior to performing this task, the following equipment must be available:
1.
WaveStar
®
CIT PC
2. CAT5 crossover LAN cable with RJ-45/RJ-45 connectors (see chapter 4,
4-48, “CIT connection (LAN crossed)” (p. 4-74)
Prerequisites
Prior to performing this task, you must have done the following:
1. Logged in to
WaveStar
®
CIT as Super User (see chapter 5, section
) if
WaveStar
®
CIT User Login has been
enabled during
WaveStar
®
CIT installation.
2. Logged in to the NE.
Procedure
Complete the following steps to change a network element’s name:
.................................................................................................................................................................................................
1
In the
WaveStar
®
CIT
System View
, select
Administration
→
Set TID...
.
Result:
The
Provision TID/NE Name
window appears.
.................................................................................................................................................................................................
2
Place the cursor in the
New TID/NE Name
text box and type the new TID observing
the following configuration rules:
•
Each NE name must be unique within the network to guarantee the reachability by
management systems and the proper interworking of NEs.
•
The following characters are allowed in an NE name:
–
Upper-case letters (“A” .. “Z”),
–
Lower-case letters (“a” .. “z”),
–
Special characters (“-”, “+”, “_”, “.”, “/”),
–
Digits (“0” .. “9”).
•
It is not allowed to start or end an NE name with a special character.
NE provisioning
.................................................................................................................................................................................................................................