Gigabit Ethernet circuit packs
.................................................................................................................................................................................................................................
Application packs
The following pack types are available:
•
GE1/SX4
•
GE1/LX4.
Cable data
Important!
Only the fiber cables with listed comcode (see Engineering Drawings)
are allowed to be used, otherwise the proper functioning of the system cannot be
guaranteed.
The fiber types are:
•
Multi Mode (MM)-minicord break-out cable (for SX applications)
•
Multi Mode (MM)-simplex cable (for SX applications)
•
Single Mode (SM)-minicord break-out cable (for LX applications)
•
Single Mode (SM)-simplex cable (for LX applications).
Connector data
LC connectors with an angled boot of 40-45 degrees are used for termination to port
units (beige connector for MM, blue connector for SM). The LC boot must remain
freely rotatable around the connector length axis after termination, in order to adjust its
orientation to the fiber routing direction without damaging the fiber.
System cabling and final assembly
.................................................................................................................................................................................................................................
365-374-187
Issue 1, December 2005
Lucent Technologies - Proprietary
See notice on first page
4-87