After the STM-1e cables have been connected and routed properly the cable bracket
(DC1007325, item 2) must still be mounted as shown in the figure below. The cable
bracket keeps the STM-1e cables within the boundary of the subrack.
Unprotected STM-1e routing
Unprotected STM-1e cabling can be done only with the use of a rack extension
(width).
General information
The STM-1e cables need to be routed loosely (with some slack) to allow service
engineers to pull out an STM-1e interface paddle board without affecting traffic of an
adjacent interface.
Figure 4-27 Mounting of the cable bracket
System cabling and final assembly
STM-1e interface
.................................................................................................................................................................................................................................
4-44
Lucent Technologies - Proprietary
See notice on first page
365-374-187