![Lucent Technologies IP-GE/2 Скачать руководство пользователя страница 163](http://html.mh-extra.com/html/lucent-technologies/ip-ge-2/ip-ge-2_installation-manual_1946302163.webp)
Coax Connector (1.6/5.6) IMS
....................................................................................................................................................................................................................................
Description
There are the following type of connectors:
•
IMS — type 3320.52.1420.0D5 (45°)
•
IMS — type 2360.52.1310.0D5 (Straight)
IMS
Important!
Use of the correct tools to ensure a proper
connection.
............................................................................................................................................................
1
Strip the cable according to the dimensions indicated in the next
figure and tin the center conductor.
Important!
The stripping lengths depend on the are connector
type!
............................................................................................................................................................
2
Pull the crimp outer ferrule over the stripped cable.
............................................................................................................................................................
3
Pull back the cable braid.
............................................................................................................................................................
4
Push the center conductor and the dielectric into the connector
housing until the dielectric stops.
............................................................................................................................................................
5
Solder the inner conductor to the center contact of the connector
housing.
............................................................................................................................................................
6
After soldering press the cover into the connector body.
............................................................................................................................................................
7
First roll the cable braid over the termination part (inner ferrule) of
the connector and pull the crimp outer ferrule over that braid.
............................................................................................................................................................
8
Crimp the outer ferrule with a Hexagon Die 4.6 — AGK 3068 by
using the Crimp Tool — AGK 2365.
Assembly Instructions
....................................................................................................................................................................................................................................
365-312-761
Issue 1, May 2004
Lucent Technologies - Proprietary
See notice on first page
A - 3 7
E
N D
O F
S