363-206-204
Releases 9 and 11 Installation Tests
Issue 9 October 1998 8-21
NOTE
:
For VT1.5 cross-connections, once the first VT drop and continue cross-
connection defines the ring direction, all other VT drop and continue cross-
connections at that node are forced to use that ring rotation.
2. At the second drop and continue node enter:
ent-crs-vt1:m-1-1-1,a-1-1:cct=dc,ring=m2:y;
7. Enter a drop and continue DS3/EC-1 cross-connect as follows:
1. At the first drop and continue node enter:
ent-crs-sts1:m-1,a:cct=dc,ring=m1:y;
NOTE
:
The parameter ring defines the direction of the continued signal. Where the
traffic must be continued on the ring transmitting to the neighboring drop
and continue node. See Note Below.
NOTE
:
Ring m1 is the ring that is received on the main-1 OLIU and is transmitted
on the main-2 OLIU.
Ring m2 is the ring that is received on the main-2 OLIU and is transmitted
on the main-1 OLIU.
NOTE
:
For VT1.5 cross-connections, once the first VT drop and continue cross-
connection defines the ring direction, all other VT drop and continue cross-
connections at that node are forced to use that ring rotation.
2. At the second drop and continue node enter:
ent-crs-sts1:m-1,a:cct=dc,ring=m2:y;
8. Check each ring timeslot to be sure it has two end cross-connections and
all other nodes have pass-throughs configured. Use Office Records and
Table 8-2 to verify this.
Protection Switch Test
This test verifies rings protection switching upon fiber cut.
1. At Site1NE1 verify that no alarms exist.
2. Enter the command
rtrv-state-path;.
3. Under the ‘act’ or active column, note whether traffic is received on M1
(main-1) OLIU or M2 (main-2) OLIU.
Содержание DDM-2000 OC-3
Страница 4: ...Issue 9 October 1998 363 206 204 Lucent Technologies ...
Страница 9: ...363 206 204 Issue 9 October 1998 Lucent Technologies ...
Страница 10: ...Issue 9 October 1998 363 206 204 Lucent Technologies ...
Страница 24: ...xxiv Issue 9 October 1998 363 206 204 ...
Страница 32: ...xxxii Issue 9 October 1998 363 206 204 ...
Страница 34: ...xxxiv Issue 9 October 1998 363 206 204 ...
Страница 58: ...1 ii Issue 9 October 1998 363 206 204 ...
Страница 74: ...2 iv Issue 9 October 1998 363 206 204 ...
Страница 143: ...363 206 204 Equipment and Rear Access Cable Installation Issue 9 October 1998 2 69 Figure 2 19 RJ 45 Plug and Face ...
Страница 144: ...2 70 Issue 9 October 1998 363 206 204 Equipment and Rear Access Cable Installation ...
Страница 192: ...3 46 Issue 9 October 1998 363 206 204 Equipment and Front Access Cable Installation ...
Страница 304: ...6 30 Issue 9 October 1998 363 206 204 Release 7 Installation Tests ...
Страница 330: ...7 24 Issue 9 October 1998 363 206 204 Release 8 Installation Tests ...
Страница 362: ...8 30 Issue 9 October 1998 363 206 204 Releases 9 and 11 Installation Tests Figure 8 2 DDM 2000 User Panel ...
Страница 395: ...363 206 204 Release 13 TARP Installation Tests Issue 9 October 1998 9 29 Figure 9 2 DDM 2000 User Panel ...
Страница 398: ...9 32 Issue 9 October 1998 363 206 204 Release 13 TARP Installation Tests ...
Страница 426: ...11 ii Issue 9 October 1998 363 206 204 ...
Страница 492: ...IN 14 Issue 9 October 1998 ...