3-32 Issue 9 October 1998
363-206-204
Equipment and Front Access Cable Installation
Notes
:
1. Inputs to the minor alarm and power minor alarm connections are normally derived from
the -48 volt alarm outputs of a SLC
®
Series 5 Carrier System power shelf. An external
ground must be connected to output-common to access the alarm. Refer to Figure 3-8
(Releases 6 and 7) or Figure 3-10 (Releases 8, 9, 11 and 13).
2. The external inputs to the miscellaneous (environmental) discretes is a contact closure
and is connected to the DDM-2000 by two leads (wires). For each of the miscellaneous
(environmental) inputs that are being used, connect one lead to input-common (TLMI-C)
and the other lead to the appropriate alarm designation (TLMI-#). Refer to Figure 3-8
(Releases 6 and 7) or Figure 3-10 (Releases 8, 9, 11 and 13).
3. J262 and J261 refer to the cable connector at the end of the dangler.
Table 3-8. Miscellaneous (Environmental) Discrete Telemetry Connections (RT)
Remote Terminal (All Releases)
Remote Terminal Additional
Environ-mental Inputs (Releases
8, 9, 11 and 13)
ED8C704-20
Cable
(J61)
ED8C724-22
Cable
(J62)
Name
Desig.
Conn.
Name
Desig.
Conn. Term Color
Color
Minor Alarm
Power Minor Alarm
Fan Control
Input-Common
MN
PMNT-IN
FAN-CTL
TLMI-C
J262 Env. Input - #20
Input-Common
TLMI-20
TLMI-C
J261
4
18
23
9
W-O
R-BR
O-BK
S-W
W-BL
BR-W
Env. Input - #1
Env. Input - #2
Env. Input - #3
Env. Input - #4
TLMI-1
TLMI-2
TLMI-3
TLMI-4
17
15
13
11
BR-R
G-R
O-R
BL-R
Env. Input - #5
Env. Input - #6
Env. Input - #7
Env. Input - #8
TLMI-5
TLMI-6
TLMI-7
TLMI-8
7
5
3
1
BR-W
G-W
O-W
BL-W
Env. Input - #9
Env. Input - #10
Env. Input - #11
Env. Input - #12
TLMI-9
TLMI-10
TLMI-11
TLMI-12
Env. Input - #16
Env. Input - #17
TLMI-16
TLMI-17
16
14
12
10
R-G
R-O
R-BL
W-S
W-G
G-W
Env. Input - #13
Env. Input - #14
Output-Common
Env. Output - #1
TLMI-13
TLMI-14
TLMO-C
TLMO-1
Env. Input - #18
Env. Input - #19
TLMI-18
TLMI-19
8
6
21
19
W-BR
W-G
BL-BK
S-R
W-O
O-W
Env. Output - #2
Env. Output - #3
Env. Output - #4
No Connection
TLMO-2
TLMO-3
TLMO-4
NC
Env. Input - #21
TLMI-21
24
22
20
2
BK-O
BK-BL
R-S
W-BL
BL-W
Содержание DDM-2000 OC-3
Страница 4: ...Issue 9 October 1998 363 206 204 Lucent Technologies ...
Страница 9: ...363 206 204 Issue 9 October 1998 Lucent Technologies ...
Страница 10: ...Issue 9 October 1998 363 206 204 Lucent Technologies ...
Страница 24: ...xxiv Issue 9 October 1998 363 206 204 ...
Страница 32: ...xxxii Issue 9 October 1998 363 206 204 ...
Страница 34: ...xxxiv Issue 9 October 1998 363 206 204 ...
Страница 58: ...1 ii Issue 9 October 1998 363 206 204 ...
Страница 74: ...2 iv Issue 9 October 1998 363 206 204 ...
Страница 143: ...363 206 204 Equipment and Rear Access Cable Installation Issue 9 October 1998 2 69 Figure 2 19 RJ 45 Plug and Face ...
Страница 144: ...2 70 Issue 9 October 1998 363 206 204 Equipment and Rear Access Cable Installation ...
Страница 192: ...3 46 Issue 9 October 1998 363 206 204 Equipment and Front Access Cable Installation ...
Страница 304: ...6 30 Issue 9 October 1998 363 206 204 Release 7 Installation Tests ...
Страница 330: ...7 24 Issue 9 October 1998 363 206 204 Release 8 Installation Tests ...
Страница 362: ...8 30 Issue 9 October 1998 363 206 204 Releases 9 and 11 Installation Tests Figure 8 2 DDM 2000 User Panel ...
Страница 395: ...363 206 204 Release 13 TARP Installation Tests Issue 9 October 1998 9 29 Figure 9 2 DDM 2000 User Panel ...
Страница 398: ...9 32 Issue 9 October 1998 363 206 204 Release 13 TARP Installation Tests ...
Страница 426: ...11 ii Issue 9 October 1998 363 206 204 ...
Страница 492: ...IN 14 Issue 9 October 1998 ...