Chapter 2
Getting Started
Cajun M770 ATM Switch User’s Guide
9
Setting the IP address
To access and manage an M770 ATM Switch remotely, for example using Telnet or
SNMP, an IP address must be set for the switch.
You will need to decide whether the M770 ATM Switch will use BOOTP to acquire
its IP address or whether you wish to set it manually.
If you plan to use BOOTP, make sure a BOOTP server is on the same ELAN as the
M770 ATM Switch management LEC, or there is a route from a BOOTP server to
the ELAN. For more information about managing the Management LEC, see
Chapter 11. You will need to set the IP address of the M770 ATM Switch to BOOTP
(this is the default IP setting for a new M770 ATM Switch). The M770 ATM Switch
will then attempt to learn its IP address using the BOOTP protocol.
If you plan to set the IP address manually, first ensure that the terminal or terminal
emulator is connected to the serial interface of the Master Agent. The IP address of
the switch can only be seen on the Master Agent (the Master Agent module’s
“NMA” LED will light ON). For example, if you want to set the IP address to be
149.49.46.61 with a subnet mask 255.255.255.0, and a gateway IP address
149.49.46.150, you should perform the following steps:
For more information about setting IP addresses, see ‘Configuring the Cajun M770
ATM Switch Address Information’ in Chapter 4, Managing Miscellaneous
Commands.
Note:
Changing the IP address commands will take effect immediately, and will
disrupt IP traffic (for example, Telnet or SNMP) that is going to the M770 ATM
Switch.
M15-155s8:/>ip address 149.49.46.61 255.255.255.0
M15-155s8:/>ip gateway 149.49.46.150
Содержание CAJUN M770
Страница 2: ...2 Cajun M770 ATM Switch User s Guide...
Страница 14: ...xii Cajun M770 ATM Switch User s Guide...
Страница 54: ...Chapter 4 Managing Miscellaneous Commands 36 Cajun M770 ATM Switch User s Guide...
Страница 64: ...Chapter 5 Managing Physical Ports 46 Cajun M770 ATM Switch User s Guide...
Страница 106: ...Chapter 6 Managing Virtual Ports 88 Cajun M770 ATM Switch User s Guide...
Страница 112: ...Chapter 7 Managing Module Hardware 94 Cajun M770 ATM Switch User s Guide...
Страница 122: ...Chapter 8 Managing PVC Connections 104 Cajun M770 ATM Switch User s Guide...
Страница 158: ...Chapter 11 Managing the Management LEC 140 Cajun M770 ATM Switch User s Guide...
Страница 176: ...Chapter 13 LANE Services 158 Cajun M770 ATM Switch User s Guide...
Страница 266: ......