background image

Instruction Manual

REV 08/11/17

WARNING: 

Read carefully and understand all INSTRUCTIONS before operating. Failure to follow the safety
rules and other basic safety precautions may result in serious personal injury.
Save these instructions in a safe place and on hand so that they can be read when required. 
Keep these instructions to assist in future servicing.

35L Oil Control Valve

Содержание 18063521

Страница 1: ...efore operating Failure to follow the safety rules and other basic safety precautions may result in serious personal injury Save these instructions in a safe place and on hand so that they can be read when required Keep these instructions to assist in future servicing 35L Oil Control Valve ...

Страница 2: ...here are certain applications for which this equipment was designed It will do the job better and more safely at the capacity for which it was intended Do not modify this equipment and do not use this equipment for a purpose for which it Was not intended 4 Check for damaged parts Before using this product carefully check that it will operate properly and perform its intended function Check for dam...

Страница 3: ...on factor refer to 3 Button usage part Once the meter has been installed please make sure that no air pressure shocks or particles can damage the meter Please check all connections to avoid leakage E1 TECHNICAL DETAILS EXPLODED AND PARTS LIST INSTALLATION MAINTENANCE DETAILS OF OPERATION TROUBLE SHOOTING GUIDE Item No Inlet connection Fluid Range Pressure Range Temperature Precision Viscosity Powe...

Страница 4: ...reset table total reset total For the move key entering instrument calibration mode Used together the two keys permit entering configuration mode BATTERY REPLACEMENT When replacing the battery please open the cover remove the plug and replace the battery LCD DISPLAY KEY Partial register 5 figures with moving comma from 0 1 to 99999 Indicating the volume dispensed since the reset button was last pr...

Страница 5: ...h can be reset 1234567 is the general total which cannot be reset Measurement unit change See Fig 6 Press MOVE and RESET together and hold for more than 3 seconds Zone 7 on the display is the current unit Press RESET to chose a different measurement unit and then press MOVE and hold for more than 3 seconds to confirm Reset The Resettable Total See Fig 7 When the meter is on standby press the RESET...

Страница 6: ... correction factor 1 000 20 75 18 96 1 000 1 094 1 094 1 2 3 4 5 Wait for the meter to go standby Reset the resettable total Press the MOVE key Keep it pressed until it shows similar to the right image the digit flash in zone which means the meter is under the calibration mode Press the RESET key to choose the right digit from 0 to 9 Press the MOVE key to start the next digit So the digit of corre...

Страница 7: ...actual value The volume that is displayed on the LCD is the Display Value not the Actual Value which may be slightly higher For example in the figure on the right the Display Value is 18 96 while the Actual Value is 20 75 Press the MOVE key Keep it pressed until it shows as the right fig with the digit flashing in zone Press the MOVE key to go the the next digit so that the Actual Value can be inp...

Страница 8: ...he trigger release your hand the transmission will be finished Notes When Using Cautions 1 For working condition please refer to the specification parameter list Temperature 10ºC 60ºC 2 Medium Lubricant Oil OIL CONTROL VALVE EXPLORED DRAWING MAINTENANCE If any problem please contact your local service centre Part No 1 2 3 Description Spout Meter Adapter Q ty 1 1 1 Part No 4 5 Description Handle Bo...

Страница 9: ...your distributor for repair or replacement Inspect the nozzle for damage or obstructions and replace if damaged If the problem remains contact your distributor for repair or replacement Replace the o rings and or the valve seat If the problem remains contact your distributor for repair or replacement 1 Get the meter off from the dispense system 2 Take off the protector 3 Loosing four the socket he...

Страница 10: ...rd Fix Board Seat Magnetic Rod Oval Gear O ring Meter Holder Q ty 1 1 1 1 1 2 2 1 1 Part No 2 10 2 11 2 12 2 13 2 14 2 15 2 16 2 17 Description Screw Label Screw Battery Battery Cover Screw Screw Shaft Q ty 4 1 4 1 1 4 4 2 E8 TECHNICAL DETAILS EXPLODED AND PARTS LIST INSTALLATION MAINTENANCE DETAILS OF OPERATION TROUBLE SHOOTING GUIDE ...

Страница 11: ...ty 1 1 1 2 1 1 1 1 1 Part No 4 10 4 11 4 12 4 13 4 14 4 15 4 16 4 17 4 18 Description Washer Seal Slip Pole O Ring O Ring Bushing O Ring O Ring Piston Sleeve Q ty 1 1 1 1 1 1 1 1 1 E9 TECHNICAL DETAILS EXPLODED AND PARTS LIST INSTALLATION MAINTENANCE DETAILS OF OPERATION TROUBLE SHOOTING GUIDE 4 1 4 2 4 3 4 4 4 5 4 6 4 7 4 8 4 9 4 10 4 11 4 12 4 13 4 15 4 16 4 17 4 18 4 14 ...

Страница 12: ...Intradin Shanghai Machinery Co Ltd iti fluid intradinchina com www intradin com Size 145x210mm REV 08 11 17 2 09 05 30 634 157克铜版纸 ...

Отзывы: