Содержание EGM-50TH-10S

Страница 1: ...ntermittent Grease Pump EGM 50TH 10S INSTRUCTION MANUAL LUBECORPORATION For your safety read and understand this manual thoroughly before handling the pump Keep this manual at a designated place for easy access at all times ...

Страница 2: ...the contents thoroughly before handling the pump In addition to the above the marks below will also appear in this Manual Please read the following explanation in order to handle the pump correctly Indicates referential information or points to which special attention should be paid while handling the pump If ignored the pump and or the machine could be damaged Indicates referential information or...

Страница 3: ...e third party make sure to include with the pump all the manuals and any other documents supplied with the pump Disposal of Pump Grease Make sure to dispose pump or grease as designated by National laws and or local regulations Japan LUBE Corporation LUBE Global Center 4 2 1 Anotsudai Tsu shi Mie prer 514 0131 TEL 059 253 3980 FAX 059 253 3981 China LUBE LUBRICATING SYSTEM SHANG HAI CO LTD C 3F 88...

Страница 4: ...3 Wiring 17 3 3 1 DIN connector wiring diagram 18 3 3 2 DIN connector connection procedure 19 3 4 Tubing 21 4 Setting of Timer on Machine 22 5 Refilling Grease 23 5 1 Grease 23 5 2 Replacement of grease cartridge for the cartridge type only 23 5 3 Grease replenishment method for the tank type only 25 6 Maintenance 26 6 1 Bleeding 26 6 2 Replacement of repair parts 27 6 2 1 Replacement of pumping u...

Страница 5: ... own cost Carefully read this Manual and understand the contents before handling the pump Keep this Manual at a designated place for easy access at all time This pump is handled by only personnel who have the knowledge and skill of its installation and adjustment Never modify or change this pump without prior permission from LUBE Strictly observe the instructions on the labels affixed to the pump ...

Страница 6: ...3 Do not step on label 4 Wiring Power supply 5 Signal line for type FB 6 Signal line for type L 7 Signal line for type LFB 8 Arrow label VOLTAGE DC24V RATED CURRENT 1 5A DIS PRESSURE 10MPa DIS VOLUME 10mL min MODEL CODE No SERIAL No EGM 50TH 10S 7C LFBD 101500 CLOSE ...

Страница 7: ...6 9 Refill nipple label 10 Caution label for types 2C 4C and 7C 11 Caution label for type 3P 12 Caution label for type 8P 補給用ニップル REFILL NIPPLE ...

Страница 8: ...7 1 2 2 Location of labels EGM 50TH 10S 2C D EGM 50TH 10S 4C D 2 3 10 2 3 10 4 4 ...

Страница 9: ...8 EGM 50TH 10S 7C D EGM 50TH 10S 7C LD EGM 50TH 10S 7C LFBD EGM 50TH 10S 3P D H L 補給用ニップル REFILL NIPPLE 1 2 3 4 10 2 3 11 6 LD 7 LFBD 4 9 ...

Страница 10: ...9 H L 補給用ニップル REFILL NIPPLE EGM 50TH 10S 8P D 2 3 12 4 9 ...

Страница 11: ...d 200 mL cartridge Dedicated 400 mL cartridge Dedicated 700 mL cartridge Tank 3P 260 mL Tank 8P 800 mL Motor life 1 500 hours NLGI 00 is 500 hours Solenoid life 3 million times Manual switch type 7C LFBD only Maximum operating voltage 24 VDC Maximum operating current 3 A Inductive load Contact type A contact Grease level switch type 7C LFBD only Maximum operating voltage 24 VDC Maximum switching c...

Страница 12: ... EGM 50TH 10S 2C D EGM 50TH 10S 4C D Caution label Cartridge cover Mounting hole Pump flange Discharge port Rc1 8 Air bleeding valve Caution label Cartridge cover Pump flange Discharge port Rc1 8 Air bleeding valve Pumping unit Relief unit Pumping unit Relief unit DIN connector 24 VDC input with LED DIN connector 24 VDC input with LED Mounting hole ...

Страница 13: ... 7C LFBD EGM 50TH 10S 3P D Caution label Tank 3P Mounting hole Pump flange Air bleeding valve Refill nipple Discharge port Rc1 8 Pumping unit Relief unit Caution label Cartridge cover Mounting hole Pump flange Air bleeding valve DIN connector 24 VDC input with LED DIN connector signal output Discharge port Rc1 8 Pumping unit Relief unit Logo label Manual switch DIN connector 24 VDC input with LED ...

Страница 14: ...04 262 5 175 133 8 5 12 5 19 43 12 補給用ニップル REFILL NIPPLE EGM 50TH 10S 8P D Caution label Tank 8P Mounting hole Pump flange Air bleeding valve Refill nipple Discharge port Rc1 8 Pumping unit Relief unit DIN connector 24 VDC input with LED ...

Страница 15: ... 6 2 Replacement of repair parts Relief unit For the replacement procedure refer to 6 2 Replacement of repair parts Special tool for replacing repair parts 2 Filter For the replacement procedure refer to 6 2 Replacement of repair parts For 7C LD and 7C LFBD 531402 For 7C D 531403 G3 4 M14 1 1 Punch Mark ...

Страница 16: ...he pump could fall itself and cause injury Be sure to fix the pump against the vertical and flat surface which can sustain its weight sufficiently Mount and fix the pump firmly using four 4 M8 bolts through φ9 holes LUBE recommends anti vibration rubber to be applied when the pump is exposed to vibration Be sure to allow necessary space as marked in the chart below for operation and maintenance ar...

Страница 17: ...sary space mm EGM 50TH 10S 2C D 2 1 A 150 B 200 EGM 50TH 10S 4C D 2 1 A 350 B 200 EGM 50TH 10S 7C D 2 2 A 250 B 200 EGM 50TH 10S 7C LD EGM 50TH 10S 7C LFBD EGM 50TH 10S 3P D 2 2 A 250 B 200 EGM 50TH 10S 8P D 3 3 A 300 B 200 The weight of grease is excluded B B A ...

Страница 18: ...VDC power supply is likely to come in contact with your hand machine exterior or any other surrounding object use an insulated wire of less than 30 m The LED of the DIN connector 24 VDC input lights when the pump starts Only qualified personnel for electrical work should connect wiring EGM 50TH 10S DIN connector 24 VDC input with LED Used wire outer diameter φ4 5 to 6 mm Lead wire sectional area 0...

Страница 19: ...10S 2C D EGM 50TH 10S 4C D EGM 50TH 10S 7C D EGM 50TH 10S 3P D EGM 50TH 10S 8P D EGM 50TH 10S 7C LD EGM 50TH 10S 7C LFBD 1 2 24VDC 0V 1 2 3 COM グリースレベルスイッチ 手動スイッチ 1 2 3 COM グリースレベルスイッチ 1 2 24VDC 0V 1 2 24VDC 0V Grease level switch Manual switch Grease level switch ...

Страница 20: ...nnect wires Strip the cable end and wires 25 mm of cable sheath and 5 mm of wire sheath and then insert the cable end through 1 a tightening gland 2 a gland washer 3 a gland gasket and 4 a connector cover Remove the screw Insert a flat head screwdriver in the point marked by and then pull the terminal out 4 3 2 1 Untighten the terminal screw with a flat head screwdriver Tighten the stranded wire W...

Страница 21: ...rding to the wiring method Step 6 1 24 VDC 2 0 V 3 Earth 1 Manual switch 2 Grease level switch 3 COM Use the following wire for the DIN connector Wire outer diameter φ4 5 to 6 mm Lead sectional area 0 75 mm2 max When carrying out wiring check for detachment When using both the manual switch and the grease level switch with the DIN connector signal input their COM inputs shall be in the same polari...

Страница 22: ...sealing 3 4 Tubing connection Connect tubing to the machine to the discharge port Rc1 8 Use tubing good for the pressure 10 MPa or higher Fix the joint with hands and then tighten it 2 5 two and a half to 3 three turns with a spanner Proper torque for fastening 7 1 N m After connection make sure there is no grease leakage from the joint Make sure to bleed air from the tubing and the pump after con...

Страница 23: ... cycle as defined below If these instructions are not followed the pump will not operate 1 Power supply from the machine controller for the pump ON 2 Discharge timer ON Timer on the machine 3 Interval timer ON Timer on the machine 4 Repeat from 2 to 3 Power supply Discharge timer Interval timer ON ON ON ...

Страница 24: ...EGM 50TH 10S 8P D 800 mL tank 5 2 Replacement of grease cartridge for the cartridge type only After the specified amount of grease has been consumed and the cartridge has shrunk follow the procedure below to replace the cartridge Use only the cartridges we designate Using cartridges other than the ones we designate may damage not only the system of this equipment but also important machine parts C...

Страница 25: ...dge CCW and remove it 3 Mount a new cartridge Discharge a small amount of grease from the cartridge first and mount the cartridge by turning it CW During replacement be careful no air and or foreign particle is introduced 4 Put the cover back and turn it CW with hands until it stops ...

Страница 26: ...his point be careful not to allow air or foreign particle to enter the tank Use only grease that we designate Our designated grease NLGI No 00 0 and 1 Lithium based We recommend that only manually operated grease guns be used The reservoir should be filled in a slow steady manner Use of Pneumatic or Electric Grease Guns may intro duce air or apply too much pressure into the reservoir which may res...

Страница 27: ...c 2 Activate the pump Air and grease come out from the hole at the end of the valve 3 When only grease comes out stop the pump 4 Manually tighten the air bleeding valve clockwise and then rotate it by 20 5 N m to tighten Air and grease often splash out from air bleeding valve Wear safety glasses during air bleeding Air bleeding valve Spanner Loose Tighten WARNING ...

Страница 28: ...rom the pump 2 Apply the provided grease to the retainer on the pumping unit Apply the grease to the O rings as well Failure to do will cause the O rings to break when installed 3 Remove the cap of the retainer and then pushing the pumping unit into the pump turn the special tool clockwise to secure the pumping unit Reference torque 15 N m Special tool Loose Tighten Pumping unit Apply the provided...

Страница 29: ...n the relief assembly An O ring will break if is installed with no grease applied to it Lastly fit in the cap Reference torque 10 N m for reference only The special tool can only fit in the outer groove Never insert the special tool into the inner groove to rotate it because doing so changes the set pressure Outer groove Apply the provided grease to the O rings Special tool Relief unit Inner groov...

Страница 30: ...wo fingers to remove it by turning it to the left or the right If it is too difficult to pick up the filter with your fingers use a tool such as pliers to pinch the filter to remove it by turning it to the left or the right When using a tool such as pliers be careful not to pinch the filter too hard and damage the cartridge adapter 2 Do not damage the Gasket while removing with a flat head screwdr...

Страница 31: ...Filter for 7C LD 7C LFBD 531402 Replace the filter once in about two years or at the time of replacing around ten cartridge containers we recommend the more frequent one 1 Wipe out grease attached around the filter and then hold the filter between two fingers to remove it by turning it to the left or the right If it is too difficult to pick up the filter up with your fingers use a tool such as pli...

Страница 32: ...th a finger cushion until it reaches the bottom 3 After installing the filter check that the level switch moves up and down When the filter is replaced some air enters into the pump Be sure to bleed air Refer to 6 1 Bleeding air ...

Страница 33: ... ambient temperature do not match Check NLGI and ambient temperature Pump does not operate Check the wiring of power supply and if it is wrong correct the wiring Check the supply power voltage and if it is out of specification correct it If the motor operation time exceeds 1 500 hours NLGI 00 500 hours or if the number of solenoid operation cycles exceeds 3 million contact us Air in the pump Bleed...

Страница 34: ...res for Air in the pump and Air in the tubing Due to a low level of grease in the tank or the cartridge air is introduced into the pump Replenish with grease of the same brand and grade as those of the currently used grease or replace the cartridge with a new one After that bleed air The distributer the valve and the grease supply pipe does not discharge grease No grease is filled in the grease su...

Страница 35: ...ten it 2 3 turn with a spanner etc 3 5 OD 6 mm copper tubing steel tubing Undercut joint Turn the nut part with hands until it stops and then tighten it 1 4 turn with a spanner etc 21 OD 8 mm copper tubing steel tubing Undercut joint Turn the nut part with hands until it stops and then tighten it 1 4 turn with a spanner etc 25 Taper screw for tubing Rc1 8 Pump discharge port junction Turn the unde...

Страница 36: ... operation Foreign particles from outside or generated inside of the system Condensation of the moisture in the air due to change in temperature or separation of grease ingredients Measures 1 At the time of cartridge exchange connection mouth not stick the foreign particles attention enough 2 Keep the grease for refilling in the proper place If the system is installed and or grease is stored outdo...