Alfa LU-VE is a trademark registered and owned by LU-VE Group.
Alfa LU-VE reserves the right to change specifications without prior notification.
5. Close carefully
When opening/closing the drip tray, pay atten-
tion in order to avoid interference between
impellers and fan collars.
-
A.Rottigni
31188585
LU-VE S.p.A.
21040 Uboldo (VA) ITALIA - Via Caduti Della Liberazione, 53
Tel: 00390296716.1 - Fax: 003996780560
www.luve.it - e-mail: [email protected]
CUSTOMER
ISSUE
CHANGE REASON
CHANGE DATE
DRAWN BY
STATUS
MATERIAL CODE
PROJECTION
GENERAL TOL.
DESCRIPTION
WEIGHT
KG
U.M.
MATERIAL
DRAW DATE
CREATED BY
APPROVAL DATE
APPROVED BY
IT14 - ±1°
03/07/2020 A.Rottigni
00
-
A.Rottigni
03/07/2020
Controlled
This drawing is the property of LU-VE Group, any reproduction and/or distribution without LU-VE Group approval is unlawful.
STICKER_FMD_FAN SHROUD
0
Thick.
1,2 mm
03/07/2020
PVC, Non plastificato
mm
30
210
DIMENSIONI: 210 x 30 mm
SCRITTE: colori (--)
FONDO: trasparente (--)
MATERIALE: PVC autodesivo
(tipo mactact)
cod.8129_90 micron
DIMENSIONS: 210 x 30 mm
WRITTEN: colors (--)
BACKGROUND: transparent (--)
MATERIAL: PVC self-adhesive
(type mactact)
code 8129_90 micron
4 Transport and storage
During transportation the heat exchanger must be handled with all required care. Any instruction or
warning signs attached to the heat exchanger or the packaging must be followed. Avoid shocks or
continuous vibrations during transport. These may cause damage to the product. If required, con-
sult Alfa LU-VE and disassemble during transport any parts that are likely to be set into vibration.
Air heat exchangers must be adequately fixed on the transport vehicle. If temporary storage of the
heat exchanger is required, the following points should be observed:
• Store the heat exchanger in its packing, in a dry place with sufficient protection against sun and
other environmental influences.
• Always place air heat exchangers on an even surface.
• Do not stack air heat exchangers unless explicitly indicated this is allowed.
• Storage temperature between -40° C and +50 °C.
• Never open or remove the Schrader valves before unit installation. Overpressure in the coil must
be maintained.
Shelf life of air coolers is one year. If longer storage periods occur, check:
• Proper functioning of the fan motor.
• Mounting brackets, lifting lugs and fan fixings for corrosion.
6. Refer to instruction manual
Manual must be carefully examined and instruc-
tions should be followed up at all times.
7. Eurovent
The Optigo SFMD series machines use the
same heat exchange components as the corre-
sponding Optigo FMD series models and pro-
vide the same performance. The Optigo SFMD
series machines can work with HFC category A1
refrigerants.