LTE TOUCHCLAVE-R Скачать руководство пользователя страница 1

Page 1 of 35 

 

USER MANUAL 

Part 1 – all users

 

 
 

TOUCHCLAVE-R AUTOCLAVES 

 
 

 
 
 

ADVANCED 
STERILIZING 
TECHNOLOGY

 

 
 

 
 
 

 

 

 

 

 

 

TCR-AUTOCLAVE 
PART 1 – ALL USERS 

Issue 1 

FM 23948 

0617 

Содержание TOUCHCLAVE-R

Страница 1: ...Page 1 of 35 USER MANUAL Part 1 all users TOUCHCLAVE R AUTOCLAVES ADVANCED STERILIZING TECHNOLOGY TCR AUTOCLAVE PART 1 ALL USERS Issue 1 FM 23948 0617...

Страница 2: ...Page 2 of 35...

Страница 3: ...of LTE Whilst all reasonable precautions have been taken to ensure the accuracy and relevance of this document LTE does not accept liability for any errors or omissions or for any damage or loss resul...

Страница 4: ...Page 4 of 35...

Страница 5: ...6 4 1 Locks 16 4 2 Restrictions on door operation 16 5 THE CONTROL SYSTEM RUNNING A CYCLE 17 5 1 Starting the cycle 17 5 2 Cycle in progress 18 5 3 Faults 18 5 4 Cooling Override 19 5 5 Finishing the...

Страница 6: ...Page 6 of 35...

Страница 7: ...s which cannot be accessed by Operators and Supervisors 1 3 Overview of Touchclave R autoclaves Autoclaves are steam sterilizers which operate by injecting steam under pressure into the chamber or ves...

Страница 8: ...ses to protect hands arms and eyes when loading or unloading the chamber since the load temperature may be as high as 100o C when moving the autoclave for example during installation remember that its...

Страница 9: ...s The automatic water fill requires a piped water supply to be available in the building near the autoclave Category 3 Effluent Retention This protects the operator by filtering all non condensable ga...

Страница 10: ...um capacity for each chamber size is as follows Model 0 5 litre bottles 1 litre bottles 2 litre bottles 1 litre flasks 2 litre flasks TCR 40 H 14 9 5 6 2 TCR 60 H 21 14 8 8 4 TCR 60 V 2 tier basket 12...

Страница 11: ...e has been reached Sterilizing During this stage the cycle achieves its objective Whilst the sterilizing temperature can be set for any given cycle at any value between 1050 C and 1360 C the values mo...

Страница 12: ...ERATURE STERILIZING TIME DRYING RATE FABRICS Porous 134 3mins 3mins but can be extended FABRICS Porous 121 15mins 15mins INSTRUMENT Porous 134o C 3 minutes 3mins but can be extended INSTRUMENT Porous...

Страница 13: ...he selected cycle with its temperatures and pressures When the autoclave is on standby a screen such as the one shown below on the left appears with the door control UNLOCK button When a cycle is bein...

Страница 14: ...ens show the values for each of the parameters or variables in the cycle They appear in either browse or sequential mode The browse screen illustrated below on the left has and buttons so that the use...

Страница 15: ...not be executed for any reason An example is shown below When the Warning Screen is touched as indicated the system will return to the previous screen Some actions require confirmation by the operator...

Страница 16: ...reen such as that illustrated below on the right will appear The unlocking sequence can be stopped by touching the ABORT button UNLOCK Chamber 1013 mBar Vent 019 6 DegC Load 023 2 DegC Chamber 1013 mB...

Страница 17: ...the AUTO button By selecting automatic start the cycle can be started at a later time This may be useful to enable the autoclave to be warmed up before a sterilization cycle starts or to allow a steri...

Страница 18: ...tegrity of the cycle has been compromised and it begins a pre determined fault sequence of stages in order to abort the cycle in the safest possible way All cycles during which an alarm condition has...

Страница 19: ...oad when it is suddenly exposed to ambient air temperature It is recommended that the user draws up a procedure for use of the Cooling Override function and that its availability is limited to supervi...

Страница 20: ...Page 20 of 35 5 6 Sample cycle printout The following is a sample of the printout for a sterilizing cycle...

Страница 21: ...will depend upon the Drying Drying Pressure options on autoclave Boost Enable Sterilize Time Sterilize Temp High Pressure Point Pulse Quantity Heatup Sterilization Set Temp Pre Vacuum Set Time Low Pr...

Страница 22: ...rence purposes and may help the user to determine the best cycle for a given load When Data Archiving is accessed on the main menu by touching the command the following screen will appear View Print C...

Страница 23: ...receding section The Reset button is only used when no cycle is running 6 7 Status By selecting Status a list of the following information display screens appears Machine Information Displays the type...

Страница 24: ...nctions can be selected from the cycle sub menu Print Cycle Prints full details of the cycle and its parameters at each stage Cycle Name Allows a cycle to be named or re named Cycle Allows a user leve...

Страница 25: ...2 50 C Sterilization Sterilize Time Sterilize Temperature Logging Interval The purpose of the autoclave is to sterilize the load effectively and the appropriate Sterilize Time measured in seconds wil...

Страница 26: ...on allows the User to be re named Edit Other This function displays details of Users who have a lower Level than the User Users who is currently logged on to the system Touching the CHANGE button allo...

Страница 27: ...n the cycle has finished the User will be warned that this function was used and will not be permitted to move on to door control until the User s password has been entered Door control will continue...

Страница 28: ...clamps onto the seal Air is then applied behind the seal to ensure full sealing If the seal has been damaged it will not be able to seal fully in which case the autoclave should not be run If a cycle...

Страница 29: ...of the chamber Finally any excess seal should be pressed firmly in to the groove Any attempt to fit the seal in one movement or to stretch the seal may result in a poor fit and should be avoided A po...

Страница 30: ...f the autoclave If there is no Automatic Drain Down fitted to the autoclave the chamber should be drained and cleaned manually at least once per week The procedure for manual draining is illustrated b...

Страница 31: ...er cannot detect the paper end correctly 1 Make sure that the printer is not receiving data otherwise data may be lost 2 Open the paper roll cover by applying your fingers on both sides of the printer...

Страница 32: ...cover by pushing the Knob to the right and pull forward 2 Cut the edge of the paper as per the following drawing 3 Insert the paper into the printer paper insertion slot in the printer mechanism If au...

Страница 33: ...from an authorized distributor It is advisable to keep a stock of such parts in order to avoid interruptions in the operation of the autoclave Part no Quantity Description Availability 710211 1 Air I...

Страница 34: ...e health of our Service personnel This is a requirement of the Health Safety at Work Act of 1974 and to meet our mutual responsibilities we will request you to complete a Safety Clearance Certificate...

Страница 35: ...y to get you operational again 8 4 2 Full training is available for the users in the various operational procedures to ensure optimum performance 8 4 3 To ensure that the equipment meets NAMAS Nationa...