SCSI Registers
4-81
HTH
Handshake-to-Handshake Timer Expired
0
This bit is set when the handshake-to-handshake timer
expires. The time measured is the SCSI Request to
Request (target) or Acknowledge-to-Acknowledge
(initiator) period. See the description of the
register, bits [7:4], for more information on
the handshake-to-handshake timer.
Register: 0x44
SCSI Longitudinal Parity (SLPAR)
Read/Write
SLPAR
SCSI Longitudinal Parity
[7:0]
This register performs a bytewise longitudinal parity
check on all SCSI data received or sent through the SCSI
core. If one of the bytes received or sent (usually the last)
is the set of correct even parity bits, SLPAR should go to
zero (assuming it started at zero). As an example,
suppose that the following three data bytes and one
check byte are received from the SCSI bus (all signals
are shown active HIGH):
A one in any bit position of the final SLPAR value would
indicate a transmission error.
The SLPAR register is also used to generate the check
bytes for SCSI send operations. If the SLPAR register
contains all zeros prior to sending a block move, it
7
0
SLPAR
x
x
x
x
x
x
x
x
Data Bytes
Running SLPAR
–
00000000
1. 11001100
11001100 (XOR of word 1)
2. 01010101
10011001 (XOR of word 1 and 2)
3. 00001111
10010110 (XOR of word 1, 2 and 3) Even Parity
4. 10010110
00000000
Содержание LSI53C895A
Страница 1: ...S14028 B LSI53C895A PCI to Ultra2 SCSI Controller TECHNICAL MANUAL A p r i l 2 0 0 1 Version 2 2...
Страница 6: ...vi Preface...
Страница 16: ...xvi Contents...
Страница 222: ...4 114 Registers...
Страница 260: ...5 38 SCSI SCRIPTS Instruction Set...
Страница 298: ...6 38 Electrical Specifications This page intentionally left blank...
Страница 302: ...6 42 Electrical Specifications This page intentionally left blank...
Страница 330: ...6 70 Electrical Specifications This page intentionally left blank...