2-36
Modulator Architecture
Figure 2.22 NCO Loop Diagram
2.12.2 Acquisition Phase Using the Frequency Measurement Unit
During the acquisition phase, the NCO bases the measurement on the
assumption that the byte clock on the ICLK input has a duration of either
of n
−
1, n, or n + 1 PCLK cycles and that the input stays within these
bounds for the duration of the measurement. You can program the
duration in multiples of 256-byte clock cycles in the REF_DUR register
(see Section 4.2.7, “Registers 21 and 22,” page 4-14). The NCO control
register (see Section 4.2.3, “Register 14,” page 4-12) can control the start
of the measurement, and the Measurement Done bit in register 13
indicates successful completion. If bit 2 of Register 14 enables an
interrupt, the measurement generates it.
After completion of the measurement, the host reads the number of byte
clock cycles found with the appropriate length of n, n + 1 and n
−
1 (from
NM_COUNT, N_COUNT, NP_COUNT—see Sections 4.2.10 through
4.2.12), as well as the value of n (from N_PCLK—see Section 4.2.9).
Frequency
58
CNT_I
CNT_O
NCO
phase_gain
EXOR
Step
OCLK
Interpolator
enable_phase_loop = 1
Byte Clock
If Serial
Virtual FIFO for Automatic
NPCLK,
N_COUNT, NP_COUNT,
ICLK
Threshold
Step Correction
Frequency Acquisition
Phase Loop
Divider
Divider
(for Frequency Selection)
Ctrl
Measurement Unit
NM_COUNT
Содержание L64777
Страница 1: ...L64777 DVB QAM Modulator Order Number I14031 A Technical Manual June 2000...
Страница 10: ...x Contents...
Страница 14: ...1 4 Introduction...
Страница 90: ...5 10 Signals...
Страница 110: ...A 8 Programming the L64777 in Serial Host Interface Mode...
Страница 116: ...C 2 Monitoring Device Internal Signals...
Страница 124: ......