background image

3ware® 9690SA 

High-Performance Serial Attached SCSI (SAS) RAID Controller 

Product Brief

LSI 3ware 9690SA

K E Y   F E A T U R E S

n

   Scalable to 128 SAS and/or 

Serial ATA devices 

n

   PCI Express x8 host interface

n

   Configuration flexibility with four 

configuration options 
– 8 internal ports   
– 8 external ports  
– 4 internal/four external ports  
– 4 internal ports

n

   SAS, SATA, and SATA II features, including 

3Gb/s and NCQ

n

   512MB DDR2 533 ECC protected memory

n

   Simultaneous double parity generation 

to maximize RAID 6 performance

n

   StorSwitch™ 8th generation non-blocking 

switch fabric for maximum controller  
 throughput

n

   StreamFusion optimizes I/O accesses to 

maximize application performance under  
 heavy workloads

n

   StorSave BBU with write journaling

  optimizes data protection and 
  performance; remote battery support

n

   Low-profile form factor

n

   RAID levels 0, 1, 5, 6, 10, 50, and

  Single Disk 

It’s Time for SAS

3ware pioneered the way for SATA and now 
capitalizes on time-proven serial storage 
expertise to take users from parallel SCSI to 
SAS.  The 9690SA seizes the moment to enter 
the market just as SAS hard drives, expanders 
and backplanes are more widely available and 
as enterprise infrastructures align to realize the 
potential of Serial Attached SCSI. As SAS makes 
inroads into the SCSI market, users will look 
to SAS to provide expanded connectivity and 
greater scalability and to the 3ware 9690SA for 
peace of mind.

Connect, Expand, Protect with SAS

 

End users will enjoy configuration flexibility 
with four low profile PCI Express controller  
options: eight internal ports, eight external 
ports, four internal/four external ports, or four 
internal ports. Compatibility with industry  
standard SAS  expanders will maximize  
flexibility. Each 9690SA SAS controller scales  
to support 128 SAS and/or SATA devices.  

Advanced 3ware RAID architecture and SAS, 
SATA, and SATA II performance features, includ-
ing 3Gb/s and NCQ, help rocket the 9690SA to 
RAID 5 and RAID 6 performance heights.  An 
optional Battery Backup Unit with integrated 
write journaling and remote battery mounting 
capability provides added data protection in the 
event of a power outage.  The 9690SA supports 
RAID levels 0, 1, 5, 6, 10, 50, and Single Disk.

The RAID 6 Difference

RAID 6 eliminates the risk of data loss if a second 
hard disk drive fails while the RAID array is 
rebuilding. Uniquely, in the 3ware RAID 6  
implementation, two sets of parity are simulta-
neously calculated, written, and rotated across 
all the drives. This second parity calculation 
enables the array to survive up to two drive  
failures without losing data, significantly  
improving fault tolerance. The 3ware RAID 6 
double parity algorithm maximizes RAID 6 
throughput, so that the 9690SA controllers 
deliver unequaled RAID 6 write performance.

Enterprise-class RAID Storage

 

SAS is the preferred interface for the direct-
attach server space, SCSI’s former mainstay.  
SAS is for mission critical applications that 
require higher levels of availability and native 
expansion.  SAS is optimized for the random 
performance requirements of the data  
center. The 9690SA’s advanced RAID features,  
SAS connectivity, and powerful 3ware  
performance architecture make it the ideal  
SCSI controller replacement. 

   

The LSI 3ware 9690SA SAS/SATA hardware RAID controllers deliver indus-
try-leading RAID 6 and RAID 5 performance, expanded scalability, robust 
fault tolerance, and multi-terabyte capacities. A PCI Express host interface, 
StorSwitch™ architecture and sophisticated SAS and SATA II features drive 
this unrivaled performance.

Block 10

Block 7

Block 4

P1 Parity

Disk #1 

Block 11

Block 8

P2 Parity

Q1 Parity

Disk #2

Block 12

P3 Parity

Q2 Parity

Block 1

Disk #3

Q4 Parity

Block 9

Block 6

Block 3

Disk #5

Striped Data with Distributed Double Parity — 

RAID 6

Host Data 

P4 Parity

Q3 Parity

Block 5

Block 2

Disk #4

RAID 6:

  Two sets of parity data, P + Q, are 

striped across disks. RAID 6 safeguards against 
data loss during rebuild mode by allowing up 
to two consecutive drive failures for maximum 
fault tolerance.

Отзывы: