GenVI Dimmer
Menu System
Operator Manual V1.0
Page 13
level whenever any valid DMX signal is detected. These channels will remain on for a
programmable “hold time” when DMX is no longer detected. GenVI switched output
provides direct power by utilising relays guaranteeing there are absolutely no
electronics in the circuit to interfere with connected loads.
3.7.5
Default Channel Settings
The default settings for channel parameters are;
ATTRIBUTE
DEFAULT SETTING
Min Level
0%
Max Level
100%
Fade Curve
Linear Curve
Control Source DMX Only
3.8
DMX MENU
Selecting
Config
,
DMX
provides menus for:
Patching DMX.
Editing and activating the DMX Loss (D) memory.
Enabling and time setting the Auto Power function.
Viewing the Input DMX signal.
3.8.1
Patch
Each GenVI dimmer unit numbers its channels from channel 1 through to channel 12.
The patch menu allows you to patch (connect) DMX slots (addresses) from your DMX lighting
controller to GenVI
channel numbers. Patches are often performed in contiguous blocks of
addresses.
Note: The
DMX Address
button on the “DMX Address” home page provides a rapid method
of patching all of the dimmers in one GenVI unit to sequential DMX slots, starting from a DMX
address that you select. See section 3.3.1.1
The “Patch” menu allows you to individually patch dimmers channels to DMX slots. Individual
patches are required when;
A particular
DMX slot number
from the lighting controller
is to control a particular GenVI
dimmer
channel
number
.
A single DMX slot number is to control multiple GenVI channel numbers.
To individually patch dimmers channels to DMX addresses press
Config
,
DMX
,
Patch
.