OWNER'S MANUAL 

LIFE PRESERVER SURVIVAL VEST 

#485-CG (Automatic)

 

 

        

WARNINGS & CAUTIONS  

 

 

The LIFE PRESERVER SURVIVAL Vest should not be worn by 
anyone under 110 lbs. or under 14 years of age. 

 

Designed for use by the U.S. Coast Guard Only. Vest  fitted with 
17 GRAM CO2 cylinder for partial inflation of bladder in the event 
of vessel capsize.  Must be orally inflated following CO2 activation. 

 

When  replacing  the  CO2  cylinder,  do  so  in  accordance  with 
instructions on the following page of this document. 

 

The  LIFE  PRESERVER  SURVIVAL  Vest  must  be  visually 
inspected  prior  to  use,  and  functionally  tested  per  inspection 
procedures. 

 

Should the LIFE PRESERVER SURVIVAL  Vest be immersed in 
either  salt  or  chlorinated  water,  the  vest  MUST  BE  FRESH 
WATER  WASHED.      Failure  to  fresh  water  wash  the  vest  may 
cause corrosion to the CO2 cylinder, firing arm, and firing pin, as 
well as damage to the fabric coatings. 

 

DO NOT inflate the LIFE PRESERVER SURVIVAL Vest prior to 
jumping  into  the  water,  if  you  are  more  than  three  to  four  feet 
above the water.  NEVER DIVE HEAD FIRST WITH THE VEST 
INFLATED.    This  could  cause  severe  personal  injuries  and 
damage the life vest. 

 

DO  NOT  inflate  the  LIFE  PRESERVER  SURVIVAL  Vest  below 
deck  in  a  boat  or  ship  as  you  may  be  trapped  under  water  in  a 
cabin, which has been flooded. 

INSPECTION

 

While LSC has designed and manufactured the inflatable to 
be as reliable as possible, periodic testing and inspection are 
necessary to ensure functional reliability.  However, prior to 
each  use  a  visual  inspection  should  be  conducted.  
Additionally, a leak inspection of the vest should not exceed 
six (6) months. The bobbin in the inflation assembly should 
be replaced every 2 years in commercial use.    

VISUAL INSPECTION

 

 (Performed prior to each use)

 

Open the CO2 cover and ensure that the service indicator is 
GREEN, If RED, do not use vest until servicing the inflation 
assembly  in  accordance  with  instructions  on  the  following 
page  of  this  document.  Inspect  the  entire  vest,  fabric, 
webbing, hardware and other components for damage. 

USING YOUR VEST

 

To don the LIFE PRESERVER SURVIVAL Vest, simply put the vest on the 
same  way  you  would  a  coat.  Close  the  front  buckle,  then  zip  up  the  front 
zipper of the vest.  Adjust the waist belt to fit snugly by pulling the two side 
straps  to  the  rear.    Tuck  the  excess  belt  under  the  vest.    Operating 
instructions are located on the left lobe inside panel.  Should you have any 
questions concerning the use of your vest or its auto-inflator, please do not 
hesitate to call LSC. 

The  primary  means  to  inflate  the  life  vest  is  manually,  using  the  beaded 
inflation lanyard (#1).  To inflate manually, jerk the beaded lanyard (located 
on your left side) down and the cell will inflate.  The automatic backup inflator 
is  a  backup  device,  which  should  inflate  the  vest.    The  automatic  backup 
inflator  will  activate  the  CO2  bottle  after  approximately  2  seconds  of 
immersion. Should the vest not inflate either manually or automatically, the 
wearer should inflate the vest using the oral inflation  tube. To orally inflate 
the vest, simply unsnap the vest, pull the oral inflation tube out located on 
your right lobe, take the dust cover off, and blow into the tube until the vest 
is firm.   

 

After  inflation  of  the  vest  in  the  water,  avoid  body  movement  or  wasteful 
expenditures of energy as much as possible and remain calm.  Should the 
inflatable cell lose some buoyancy, remove the cap on the oral inflation tube 
and blow into it.  Replace the cap on the oral inflation tube after you have 
topped-off the cell.

 

The automatic backup inflator will inflate the cell whenever exposed to water.  
Should the vest inadvertently inflate due to heavy rain or sea states, deflate 
the cell by depressing the top of the oral tube dust cover into the oral tube.  
Replace  and  service  the  inflation  assembly  in  accordance  with  the 
instructions on the following page of this document. 

 

LEAK INSPECTION (Performed Semiannually)

 

1.  Inflate  the  bladder  through  the  oral  tube  with  a  low-

pressure  air  source  (2  psi  max.)  or  by  oral  inflation.  
CAUTION:  DO NOT OVER INFLATE.  Damage to the 
bladder  will  result  from  overpressure.    After  two  (2) 
hours, recheck the bladder for pressure.  If the bladder 
has lost pressure, re-inflate and locate source of leak.  
Repair  problem  or  remove  vest  from  service.  Deflate 
the vest. 

FUNCTIONAL & LEAK INSPECTION

 (Performed Annually)

 

1.  Pull beaded lanyard to inflate the bladder.  Both 

sides of the bladder should fully deploy.  Deflate the 
cell by depressing the top of the oral tube dust 
cover into the oral tube. Service inflation assembly 
so in accordance with instructions on the following 
page of this document. 

2.  Complete Leak Inspection above. 

 

 

REPLACEMENT PARTS  

#470-CG 

  AUTO INFLATOR 

#474 

BOBBIN   

#353 

CO2 CYLINDER, 17 GRAMS 

 

 

 

 

WARRANTY

 

LSC products are warranted to the first consumer purchaser to be free from defects in material or workmanship for a period of twelve (12) 
months.  Please contact LSC for our complete Warranty information and Policies, or visit our website.

 

 

 
 