4. Parameters
4-31
Parameter
Unit
Initial
Details
Code
Name
Minimum
Maximum
P0-06
Main power input mode
-
0b00
Sets main power input.
DIGIT 1-> 0: Single-phase power
1: 3-phase power input
Caution
: Using single-phase power
may lower motor output.
DIGIT2 -> 0: Error in case of phase loss
1: Warning in case of phase loss
Power fail mode
0b00
0b11
P0-07
RST checking time
[ms]
20
Sets the time to check main power phase
loss.
RST check time
0
5000
P0-08
Displays parameter
upon start.
-
0
Sets the number for the operation status
parameter that is displayed at the start.
(Details: Refer to “4.4.1 System Parameter
Setting.")
Start up parameter
0
25
*P0-09
Regenerative overload
derating
[%]
100
Sets derating factor for checking of
regenerative resistance overload. The
overload alarm triggers quickly when the
derating value is set to 100% or below.
Regeneration derating
1
200
**P0-10
Regenerative resistance
value
[Ω]
0
Sets the resistance value for regenerative
braking resistance. If set to 0, the default
resistance value of the drive is used.
Regenerarion
brake resistor
0
1000
**P0-11
Regenerative resistance
capacity
[W]
0
Sets the capacity for the current
regenerative resistance. If set to 0, a default
resistance capacity embedded in the drive
is used.
Regenerarion brake
capacity
0
30000
*P0-12
Overload check
Base load factor
[%]
100
Indicates the load factor for starting
continuous overload checks. If set to 100 or
below, an overload check starts early and
the overload alarm triggers early.
Overload check base
10
100
P0-13
Continuous overload
warning level
[%]
50
Indicates the level of continuous overload
warning signal output. Outputs the warning
signal when the percentage value against
alarm trigger load factor is reached.
Overload Warning Level
10
100
*P0-14
Encoder output prescale
numerator
-
1
Sets the prescale numerator for encoder
output when the servo outputs an encoder
signal to the outside.
(Details: Refer to “4.4.1 System Parameter
Setting.")
Encoder out NUM.
1
16383
*P0-15
Encoder output prescale
denominator
-
1
Sets the prescale denominator for encoder
output when the servo outputs an encoder
signal to the outside.
(Details: R
efer to “4.4.1 System Parameter
Setting.")
Encoder out DEN.
1
16383
*P0-16
PWM OFF delay time
[ms]
10
Sets the time to delay until the PWM signal
actually goes off after the servo is turned off.
(Details: Refer to “4.4.1 System Parameter
Setting.")
PWM OFF delay
0
1000
Содержание L7 A001
Страница 1: ...VER 1 5...
Страница 2: ......
Страница 32: ...1 Product Components and Signals 1 20...
Страница 38: ...2 Installation 2 6...
Страница 54: ......
Страница 188: ...7 Product Specifications 7 26 L7 A020 L7 A035 Weight 2 5 kg cooling fan included...
Страница 210: ...8 Maintenance and Inspection 8 14...
Страница 211: ...9 Appendix 9 1 9 Appendix...
Страница 218: ...9 Appendix 9 8...
Страница 221: ......
Страница 222: ......